Search PubMed⌕ Search

PubMed · 11519570

Interaural correlation sensitivity.

Abstract

Sensitivity to differences in interaural correlation was measured for 1.3-ERB-wide bands of noise using a 2IFC task at six frequencies: 250, 500, 750, 1000, 1250, and 1500 Hz. The sensitivity index, d', was measured for discriminations between a number of fixed pairs of correlation values. Cumulative d' functions were derived for each frequency and condition. The d' for discriminating any two values of correlation may be recovered from the cumulative d' function by the difference between cumulative d''s for these values. Two conditions were employed: the noisebands were either presented in isolation (narrow-band condition) or in the context of broad, contiguous flanking bands of correlated noise (fringed condition). The cumulative d' functions showed greater sensitivity to differences in correlation close to 1 than close to 0 at low frequencies, but this difference was less pronounced in the fringed condition. Also, a more linear relationship was observed when cumulative d' was plotted as a function of the equivalent signal-to-noise ratio (SNR) in dB for each correlation value, rather than directly against correlation. The equivalent SNR was the SNR at which the interaural correlation in an NoS(pi) stimulus would equal the interaural correlation of the noise used in the experiment. The maximum cumulative d' declined above 750 Hz. This decline was steeper for the fringed than for the narrow-band condition. For the narrow-band condition, the total cumulative d' was variable across listeners. All cumulative d' functions were closely fitted using a simple two-parameter function. The complete data sets, averaged across listeners, from the fringed and narrow-band conditions were fitted using functions to describe the changes in these parameters over frequency, in order to produce an interpolated family of curves that describe sensitivity at frequencies between those tested. These curves predict the spectra recovered by the binaural system when complex sounds, such as speech, are masked by noise.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F Culling, H S Colburn, M Spurchise. 2001. Interaural correlation sensitivity.. https://doi.org/10.1121/1.1383296

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A low glycaemic index breakfast cereal preferentially prevents children's cognitive performance from declining throughout the morning.

This study investigated whether the glycaemic index (GI) of breakfast cereal differentially affects children's attention and memory. Using a balanced cross-over design, on two consecutive mornings 64 children aged 6-11 years were given a high GI cereal and a low GI cereal in a counterbalanced order. They performed a series of computerised tests of attention and memory, once prior to breakfast and three times following breakfast at hourly intervals. The results indicate that children's performance declines throughout the morning and that this decline can be significantly reduced following the intake of a low GI cereal as compared with a high GI cereal on measures of accuracy of attention (M=-6.742 and -13.510, respectively, p<0.05) and secondary memory (M=-30.675 and -47.183, respectively, p<0.05).

Attention↗

Inhibitory control test is a simple method to diagnose minimal hepatic encephalopathy and predict development of overt hepatic encephalopathy.

OBJECTIVES: To compare inhibitory control test (ICT), a simple/rapid test of attention, to a standard psychometric battery (SPT) to diagnose minimal hepatic encephalopathy (MHE) and predict development of overt hepatic encephalopathy (OHE) in cirrhotic patients. METHODS: Fifty nonalcoholic cirrhotics and 50 age/educational-status-matched controls were given ICT and SPT in the same sitting. Performance impaired beyond two standard deviations of controls was considered MHE in cirrhotics. ICT results (lure/target response and lures/person) were compared between controls and cirrhotics and within cirrhotics with/without MHE. Receiver-operating characteristic analysis was used to study ICT for MHE diagnosis. Twenty subjects were administered SPT and ICT twice to assess test-retest reliability. All cirrhotics were followed routinely for the development of OHE. RESULTS: Cirrhotics performed worse than controls on SPT and ICT. Using SPT, 39 cirrhotics had MHE. ICT was administered faster than SPT (15 vs 37 min). Cirrhotics with MHE had significantly higher lure (28%vs 3%) and lower target response (91%vs 96%) compared with those without MHE. Lure/person >5 had 90% sensitivity/specificity for MHE diagnosis. AUC for receiver-operating characteristic for lures alone was 95.8%. Lure and target responses were highly correlated (r= 0.9) between sessions showing high test-retest reliability. Five (10%) patients developed OHE on f/u of 26 +/- 10 months; all five had been diagnosed with MHE using ICT and SPT. None of the five patients with discordant results on SPT and ICT developed OHE. CONCLUSIONS: ICT has good sensitivity/specificity for MHE diagnosis, is reliable and is equivalent to SPT for predicting OHE development.

Attention↗