Search PubMed⌕ Search

PubMed · 11513948

Stimulus artifact removal using a software-based two-stage peak detection algorithm.

Abstract

The analysis of stimulus evoked neuromuscular potentials or m-waves is a useful technique for improved feedback control in functional electrical stimulation systems. Usually, however, these signals are contaminated by stimulus artifact. A novel software technique, which uses a two-stage peak detection algorithm, has been developed to remove the unwanted artifact from the recorded signal. The advantage of the technique is that it can be used on all stimulation artifact-contaminated electroneurophysiologic data provided that the artifact and the biopotential are non-overlapping. The technique does not require any estimation of the stimulus artifact shape or duration. With the developed technique, it is not necessary to record a pure artifact signal for template estimation, a process that can increase the complexity of experimentation. The technique also does not require the recording of any external hardware synchronisation pulses. The method avoids the use of analogue or digital filtering techniques, which endeavour to remove certain high frequency components of the artifact signal, but invariably have difficulty, resulting in the removal of frequencies in the same spectrum as the m-wave. With the new technique the signal is sampled at a high frequency to ensure optimum fidelity. Instrumentation saturation effects due to the artifact can be avoided with careful electrode placement. The technique was fully tested with a wide variety of electrical stimulation parameters (frequency and pulse width) applied to the common peroneal nerve to elicit contraction in the tibialis anterior. The program was also developed to allow batch processing of multiple files, using closed loop feedback correction. The two-stage peak detection artifact removal algorithm is demonstrated as an efficient post-processing technique for acquiring artifact free m-waves.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D T O'Keeffe, G M Lyons, A E Donnelly, C A Byrne. 2001-08-30. Stimulus artifact removal using a software-based two-stage peak detection algorithm.. https://doi.org/10.1016/s0165-0270(01)00407-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Neuropeptide Y inhibits the hyperexcitability of type A neurons in chronically compressed dorsal root ganglion of the rat.

Our recent data revealed adrenergic sensitivity in chronically compressed dorsal root ganglion (DRG) of rats. As neuropeptide Y (NPY) is a common sympathetic co-transmitter, we investigated the effect of NPY on injured DRG neurons. The expression of NPY Y1 and Y2 receptors and the effect of NPY on chronically compressed DRG neurons were studied using in situ hybridization and extracellular single fiber recording in vitro, respectively. After DRG compression, the expression of Y1 receptor was distinctly increased in large and medium-sized DRG neurons, while Y2 receptor was increased in small DRG neurons. NPY inhibited both the spontaneous activity and the excitatory effect of norepinephrine in injured DRG A-neurons. The results suggest a possibility that NPY may inhibit the hyperexcitability of injured DRG A-neurons via increased Y1 receptor following chronic compression.

Action Potentials↗

Peripartum interneuronal coupling in the supraoptic nucleus.

In the supraoptic nucleus (SON), the incidence of conducting gap junctions (gjs), as indicated by dye coupling, is low in cycling females, but dramatically elevated in nursing mothers. Functionally, this is consistent with the well-established presence of synchronous milk ejection bursts among oxytocin neurons only in the lactating rat. In situ hybridization data, however, revealed elevated gj mRNA expression on the last day of pregnancy, a time when burst firing by putative oxytocin neurons is absent. Using Lucifer Yellow dye coupling, we determined the incidence of high conductance gjs in SONs of proestrous, immediately prepartum, postpartum non-lactating, lactating day 1, and lactating day 9-10 rats. Results indicate that coupling incidence is high only at times when milk ejection bursts are known to occur, and that the elevated gj mRNA expression seen on the last day of pregnancy does not indicate conducting gjs. It is suggested that gj conductance states, but not gj expression, are modulated by plasma estradiol titers.

Action Potentials↗

Assessment of single motor unit conduction velocity during sustained contractions of the tibialis anterior muscle with advanced spike triggered averaging.

This paper describes an improved spike triggered averaging technique for the assessment of control properties and conduction velocity (CV) of single motor units (MUs) of the tibialis anterior muscle during voluntary muscle contractions. The method is based on the detection of multi-channel surface EMG signals (with linear electrode arrays) and intramuscularly recorded single MU action potentials (MUAPs). Intramuscular electrodes were inserted in the muscle taking into account the MU structural properties (innervation zone, tendon locations, length of the fibers), assessed by the linear array surface EMG detection technique. An algorithm for intramuscular EMG signal decomposition is used to identify single MUAP trains. The MUAPs detected by the intramuscular EMG decomposition algorithm were used to trigger and average the multi-channel EMG signals. CV of single averaged surface MUAPs was estimated by the use of advanced signal processing methods based on multi-channel recordings which allow to consistently reduce the variance of CV estimates compared with traditional two channel delay estimators. The number of averaged potentials can thus be limited, resulting in high temporal resolution CV estimates. The developed technique was tested on recordings from the tibialis anterior muscle in 11 volunteers during fatigue. It was shown that the method allows the assessment of single MU CV changes (fatigue) as small as 0.1 m/s with less than 2 s data epochs. The method allows reliable assessment of firing rate and conduction properties of single MUs with applications for the investigation of central and peripheral fatigue mechanisms.

Action Potentials↗