Search PubMed⌕ Search

PubMed · 11506083

Technology update.

Abstract

The history of diagnostic US is marked by a remarkable series of giant advances in technology that have had major impact on the clinical impact of sonography. As the twenty-first century begins, US is poised for additional major advances in performance and clinical impact. In the evaluation of a multitude of diseases these developments will bring improvements in screening, diagnosis, and management and extend the value of US to a greatly expanded population.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C R Merritt. 2001. Technology update.. https://doi.org/10.1016/s0033-8389(05)70287-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Type, severity, frequency and management of adverse reactions associated with ultrasound contrast agents: a systematic review and meta-analysis.

OBJECTIVES: This systematic review and meta-analysis are aimed at evaluating the incidence of adverse drug reactions (ADRs) following administration of clinically approved ultrasound contrast agents (UCAs) in adults and children, to assess risks in patients with cardiovascular disease and in pregnancy, and to evaluate the effectiveness of emergency management of severe ADRs. MATERIALS AND METHODS: A PRISMA 2020 systematic review was conducted searching PubMed, Scopus, and Embase. Two reviewers independently screened, extracted data, and assessed quality. Incidence estimates were pooled when feasible, stratified by age group, contrast agent, and administration route. RESULTS: Seventy-four studies encompassing >&#x2009;1 million adults and >&#x2009;36,000 children were included, contributing multiple analytic cohorts to the quantitative synthesis. Severe acute ADRs were extremely rare (6 and 16 cases per 100,000 in adults and children, respectively) and absent following endocavitary administration in children. Non-severe acute ADRs occurred in 11 and 8 cases per 10,000 adults and children, respectively. Delayed reactions were very rare (<&#x2009;1 case per million in adults). No significant safety differences emerged between UCA products. The incidence of ADRs in patients with cardiovascular disease was analogous to the general population. No ADRs were reported in pregnant women. Standard emergency management was effective in almost all serious cases, though rare fatalities occurred. CONCLUSION: UCAs show an excellent safety profile in adults and children, with very rare severe ADRs and few non-severe, typically self-limiting reactions. Strict adherence to recommended emergency management protocols mitigates the remaining risks, supporting safe use across a broad range of clinical indications. PROSPERO REGISTRATION: CRD42023432668. KEY POINTS: Question What is the incidence, type, and severity of acute and delayed ADRs associated with clinically approved UCAs across different patient populations? Findings Severe acute adverse reactions are very rare, and non-severe reactions are rare and self-limiting, with no significant safety differences between adults, children, or patients with cardiovascular disease. Clinical relevant UCAs show an excellent safety profile across populations. These findings support their safe clinical use as reliable alternatives to iodine-based and gadolinium-based contrast agents in routine diagnostic imaging.

Contrast Media↗

Assessment of lung ventilation by MR imaging: current status and future perspectives.

The aim of this paper is to review the present status of novel MRI techniques as a new important instrument for functional ventilation imaging. The current status and future perspectives in research and clinical applications are summarized. Morphological lung imaging is based on chest radiography and computed tomography, whereas scintigraphy is used for ventilation imaging. During recent years, MRI has emerged as a new means for functional imaging of ventilation. Aerosolized contrast agents and oxygen are used in proton imaging, whereas non-proton imaging relies on fluorine compounds, such as sulfur hexafluoride and perfluorcarbons, or on hyperpolarized noble gases, such as helium-3 or xenon-129. All the gases are administered as inhaled "contrast agents" for imaging of the airways and airspaces. In general, straightforward images demonstrate the homogeneity of ventilation in a breath-hold and allow for determination of ventilated lung. The different properties of the different compounds enable the measurement of additional functional parameters. They comprise airspace size, regional oxygen partial pressure, and analysis of ventilation distribution, ventilation/perfusion ratios, and gas exchange, including oxygen uptake. Novel MRI techniques provide the potential for functional imaging of ventilation. The next steps include definition of the value and the potential of the different contrast mechanisms as well as determination of the significance of the functional information with regard to physiological research and patient management in chronic obstructive pulmonary disease and others.

Contrast Media↗

Conformational characterization of lanthanide(III)-DOTA complexes by ab initio investigation in vacuo and in aqueous solution.

The conformational behavior of four [Ln(DOTA)(H(2)O)](-) systems (Ln = La, Gd, Ho, and Lu) has been characterized by means of ab initio calculations performed in vacuo and in aqueous solution, the latter by using the polarizable continuum model (PCM). Calculated molecular geometries and conformational energies of the [Ln(DOTA)(H(2)O)](-) systems, and interconversion mechanisms, barriers, and (13)C NMR spectra of the [Lu(DOTA)](-) complex are compared with experimental values. For each system, geometry optimizations, performed in vacuo and in solution at the HF/3-21G level and using a 46+4f(n) core electron effective core potential (ECP) for lanthanides, provide two minima corresponding to a square antiprismatic (A) and an inverted antiprismatic (IA) coordination geometry. All the systems are nonacoordinated, with the exception of the IA isomer of the Lu complex that, from in solution calculations, is octacoordinated, in agreement with experimental data. On comparing the in vacuo relative free energies calculated at different theory levels it can be seen that the nonacoordinated species dominates at the beginning of the lanthanide series while the octacoordinated one does so at the end. Furthermore, on passing along the series the IA isomer becomes less and less favored with respect to A and for the Lu complex a stabilization of the IAisomer is observed in solution (but not in vacuo), in agreement with the experimental data. Investigation of the A<-->IA isomerization process in the [Lu(DOTA)](-) system provides two different interconversion mechanisms: a single-step process, involving the simultaneous rotation of the acetate arms, and a multistep path, involving the inversion of the cyclen cycle configuration. While in vacuo the energy barrier for the acetate arm rotation is higher than that involved in the ring inversion (23.1 and 13.1 kcal mol(-)(1) at the B3LYP/6-311G level, respectively), in solution the two mechanisms present comparable barriers (14.7 and 13.5 kcal mol(-)(1)), in fairly good agreement with the experimental values. The NMR shielding constants for the two isomers of the [Lu(DOTA)](-) complex have been calculated by means of the ab initio GIAO and CSGT methods, and using a 46-core-electron ECP for Lu. The calculated (13)C NMR chemical shifts are in close agreement with the experimental values (rms 3.3 ppm, at the HF/6-311G level) and confirm the structural assignment of the two isomers based on experimental NMR spectra in solution. The results demonstrate that our computational approach is able to predict several physicochemical properties of lanthanide complexes, allowing a better characterization of this class of compounds for their application as contrast agents in medical magnetic resonance imaging (MRI).

Contrast Media↗