Search PubMed⌕ Search

PubMed · 11501623

A noninvasive estimation of hypernasality using a linear predictive model.

Abstract

The pronunciation of a speaker with a defective soft palate is marked by hypernasality and an operation may be necessary to repair the defective soft palate to reduce this hypernasality. An assessment of hypernasality is necessary to quantify the effect of the surgery. The current clinical methods for assessing hypernasality are uncomfortable or require expensive equipment. In this paper, a new quantitative method is proposed to estimate hypernasality. This method requires only a microphone and a personal computer equipped with a sound card. Zeros in the frequency response of the vocal tract system are one of the major characteristics of hypernasality. The proposed method made use of the fact that a linear predictive model with a typical order for the human vocal tract system is not accurate when the vocal tract system has zeros in its frequency response. Hypernasality was estimated by comparing the distance between the sequences of linear predictive cepstrum of low- and high-order linear predictive models. The proposed method provides a better correlation (0.58) with nasalance measured by a nasometer than Teager method (0.44) for all the data. Furthermore, the proposed method showed higher correlation of 0.84 than 0.71 of the Teager method for data with a nasalance higher than 35%. Since the proposed method needs only digitized speech data, it is much less invasive and provides an easy and cost-effective evaluation of hypernasality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D K Rah, Y L Ko, C Lee, D W Kim. 2001. A noninvasive estimation of hypernasality using a linear predictive model.. https://doi.org/10.1114/1.1380422

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗