Search PubMed⌕ Search

PubMed · 11485246

Trigeminal root recording in normal trigeminal function.

Abstract

Despite many investigations on the detection of trigeminal evoked potentials (TEP), there is still no consensus on a technique or interpretation of its components. In order to obtain clear TEP waveforms and analyze the origin of early components, we recorded TEP by the conventional far-field technique at the ipsilateral auricula as well as by near-field technique with a bipolar electrode at the trigeminal root just distal to the entry zone of its root. Trigeminal recordings were performed in nine patients with intrameatal vestibular schwannomas and in three with trigeminal neuralgia without trigeminal nerve deficits. In near-field recording at the trigeminal root, a triphasic response was recorded, with the first component occurring at 3.16 ms, 2.98 ms, and 4.16 ms following supraorbital, infraorbital, and mandibular nerve stimulation, respectively. Using conventional farfield TEP, the first component recorded at the trigeminal root occurred later than the first component in all other recordings. This suggests that the N2.0 component of far-field TEP is of extra-axial origin and the N5 component is of brainstem origin. The N13.0 component may be of cortical origin. We conclude that the N5.0 component and N5.0-N13.0 interpeak latency may be used as electrophysiological parameters of brainstem function during posterior fossa surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Naderi, C Matthies, M Samii. 2001. Trigeminal root recording in normal trigeminal function.. https://doi.org/10.1007/pl00014588

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Human epidermal membrane constant conductance iontophoresis: alternating current to obtain reproducible enhanced permeation and reduced lag times of a nonionic polar permeant.

An experimental protocol, using an initial 1 min direct current (DC) applied potential of 4 V followed by alternating current (AC), was established to: (a) increase conductance and permeability and decrease lag time for human epidermal membrane (HEM) relative to unaltered HEM and; (b) maintain constant conductance and permeability during flux studies. The protocol allowed specific permeation parameters of the membrane to be characterized under electrically enhanced, constant flux conditions. The permeability, lag time, and effective membrane thickness were determined using a nonionic polar permeant, urea, while the enhanced conductance was maintained at a constant level with AC. A tortuous pore pathway model was employed to analyze the data. The AC protocol increased membrane permeability, and decreased lag time and effective membrane thickness relative to similar parameters obtained in previous studies from unaltered HEM. Lag times ranged from 32.0 to 105.5 min, and permeability coefficients calculated from steady state fluxes ranged from 1.68 to 6.03x10(-7) cm/s for HEM samples with electrical resistance values during transport of 2.3-8.0 kOmega x cm2. Effective membrane thicknesses were calculated to range from 0.34 to 0.61 cm during AC iontophoresis. Significant additional results were obtained when the protocol was applied for two consecutive runs using the same HEM sample, with time for the HEM sample to recover between runs. During the second run, the applied potential was adjusted to reproduce the conductance obtained on the first run. Under these conditions, the consecutive runs yielded essentially the same lag time, permeability and effective membrane thickness values. These results suggest that constant fluxes can be achieved by keeping HEM electrical conductance constant during AC iontophoresis.

Electric Stimulation↗

Simplicity in complexity: the photosynthetic reaction center performs as a simple 0.2 V battery.

The photosynthetic reaction center is one of the most complicated molecular complexes. Transducing photon energy to a transmembrane electrochemical potential difference for protons, it is the direct or indirect energy source for virtually all life. We show here that it operates in a simple, battery-like manner, with a maximum potential of 0.20 V. Intriguingly this is only one fifth of the energy of the absorbed photon.

Electric Stimulation↗

Loss of reflex inhibition following muscle tendon stimulation in essential tremor.

Electrical stimulation of human upper limb muscle tendons produces a reflex inhibition (I(1)) in the same muscles. This inhibition is reduced in Parkinson's disease (PD), prompting a similar study of essential tremor (ET). In essential tremor, two of eight subjects had no discernible inhibition, even following supramaximal stimulation (< 80 mA) of the tendons from extensor digitorum communis and extensor pollicis brevis. In the remaining six subjects, the mean thresholds for I(1) in these muscles were increased by 270 and 320%, respectively, relative to controls. The maximal amplitude of the inhibition was significantly reduced in the ET group, as was the following excitation (E(1)). The latency and duration of I(1) were not different in ET subjects and controls. The maximal duration of I(1) was correlated with tremor frequency in individuals, and tendon stimulation was effective in initiating ongoing tremor cycles. These results disclose a peripheral reflex abnormality in ET that is mediated by tendon afferents and can be linked to the coexistent tremor. The response in ET was distinguished from that in PD by its different time-course and by failure of the response to appear in the antagonist muscle. The abnormality may prove a useful marker for ET, which currently lacks a definitive pathological or neurophysiological marker to support objective clinical diagnosis.

Electric Stimulation↗