Search PubMed⌕ Search

PubMed · 11477770

Strain rate imaging using two-dimensional speckle tracking.

Abstract

Strain rate images (SRI) of the beating heart have been proposed to identify non-contracting regions of myocardium. Initial attempts used spatial derivatives of tissue velocity (Doppler) signals. Here, an alternate method is proposed based on two-dimensional phase-sensitive speckle tracking applied to very high frame rate, real-time images. This processing can produce high resolution maps of the time derivative of the strain magnitude (i.e., square root of the strain intensity). Such images complement traditional tissue velocity images (TVI), providing a more complete description of cardiac mechanics. To test the proposed approach, SRI were both simulated and measured on a thick-walled, cylindrical, tissue-equivalent phantom modeling cardiac deformations. Real-time ultrasound images were captured during periodic phantom deformation, where the period was matched to the data capture rate of a commercial scanner mimicking high frame rate imaging of the heart. Simulation results show that SRI with spatial resolution between 1 and 2 mm are possible with an array system operating at 5 MHz. Moreover, these images are virtually free of angle-dependent artifacts present in TVI and simple strain rate maps derived from these images. Measured results clearly show that phantom regions of low deformation, which are difficult to identify on tissue velocity-derived SRI, are readily apparent with SRI generated from two-dimensional phase-sensitive speckle tracking.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Kaluzynski, X Chen, S Y Emelianov, A R Skovoroda, M O'Donnell. 2001. Strain rate imaging using two-dimensional speckle tracking.. https://doi.org/10.1109/58.935730

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗