Search PubMed⌕ Search

PubMed · 11420548

Using Dermabond.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F M Abenavoli. 2001. Using Dermabond.. https://doi.org/10.1097/00006534-200107000-00063

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of thermocycling on the shear bond strength of a cyanoacrylate orthodontic adhesive.

The purpose of this study was to evaluate the effects of thermocycling on the shear bond strength of a cyanoacrylate adhesive system, specifically 24 hours after bonding when the adhesive has achieved most of its bond strength and after thermocycling. Forty freshly extracted human molars were collected and stored in a solution of 0.1% (weight/volume) thymol. The teeth were cleaned, polished, and randomly separated into 2 groups: group I, cyanoacrylate adhesive debonded after 24 hours immersion in deionized water at 37 degrees C; and group II, cyanoacrylate adhesive debonded after thermocycling at 5 degrees C and 55 degrees C. The results of the t test comparing the 2 groups (t = 6.84) indicated significant differences between them (P =.0001). The cyanoacrylate adhesive at 24 hours had significantly greater shear bond strength (macro x = 7.1 +/- 3.3 MPa) than after thermocycling 500 times between 5 degrees C and 55 degrees C (macro x = 1.5 +/- 1.4 MPa). The findings indicated that the cyanoacrylate adhesive tested has clinically adequate shear bond strength at 24 hours after initial bonding but loses about 80% of its strength after thermocycling. The clinician should consider all properties of the adhesive, including no need for a curing light, working time of 5 seconds before the adhesive starts to set, and the significant decrease in bond strength after thermocycling.

Cyanoacrylates↗

Tissue adhesive and postoperative allergic meningitis.

Adhesives containing cyanoacrylate are used in many surgical procedures, including closure of skin wounds and reinforcement of intracranial aneurysm repairs. A 61-year-old woman developed fever, neck stiffness, and cerebrospinal fluid eosinophilia after an operation for an intracranial aneurysm. We suspected allergic meningitis due to a foreign substance. To detect the cause of this disorder, we did 2-day closed patch testing with the substances thought to be possible allergens. We recorded a positive reaction to methyl-2-cyanoacrylate, the main ingredient of Biobond, the tissue adhesive used in the surgery. This substance could have caused postoperative allergic meningitis.

Cyanoacrylates↗