Search PubMed⌕ Search

PubMed · 11394270

Small scale model for CFD validation in DAF application.

Abstract

A laboratory model is used to measure the generic flow patterns in dissolved air flotation (DAF). The Perspex model used in this study allows the use of laser Doppler velocimetry (LDV), a non-invasive, high-resolution (+/- 2 mm s-1) laser technique of flow velocity measurement. Measurement of flow velocity in the single-phase situation was first carried out. Air-saturated water was then supplied to the tank and measurements of bubble velocity in the two-phase system were made. Vertical flow re-circulation was observed in the flotation zone. In the bottom of the flotation zone (near the riser) secondary flow re-circulation was observed, but only in the two-phase system. Another phenomenon was the apparent movement of flow across the tank width, which may be due to lateral dispersion of the bubble cloud. Data from preliminary computational fluid dynamics (CFD) models were compared against this measured data in the case of the single-phase system. The CFD model incorporating a k-epsilon model of turbulence was found to give closer agreement with the measured data than the corresponding laminar flow model. The measured velocity data will be used to verify two-phase computational fluid dynamics (CFD) models of DAF.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Hague, C T Ta, M J Biggs, J A Sattary. 2001. Small scale model for CFD validation in DAF application.. https://pubmed.ncbi.nlm.nih.gov/11394270/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Approximation of flammability region for natural gas-air-diluent mixture.

The growing implementation of exhaust gas recirculation (EGR) in reducing NO(x) emissions of engine is of paramount motivation to perform a fundamental research on the flammability characteristics of fuel-air-diluent mixtures. In this work, the influences of EGR on the flammability region of natural gas-air-diluent flames were experimentally studied in a constant volume bomb. An assumption of critical burning velocity at flammability limit is proposed to approximately determine the flammability region of these mixtures. Based on this assumption, an estimation of the flammability map for natural gas-air-diluent mixtures was obtained by using the empirical formula of burning velocity data. The flammability regions of natural gas-air mixtures with EGR are plotted versus the EGR rate. From the comparison of estimated results and experimental measurements, it is suggested that the accuracy of prediction is largely dependent upon the formula of burning velocity used. Meanwhile, the influence of pressure on the critical burning velocity at flammability limit is also investigated. On the basis of the pressure dependence criterion, the estimation was performed for the circumstance of high temperature and pressure, and the prediction results still agree well with those of experiments.

Air↗

Composition and structure of iron oxidation surface layers produced in weak acidic solutions.

Although oxidation/passivation of iron in basic solution has been extensively investigated, there is very little information on iron corrosion in weak acidic solutions. In this work, iron surface composition and structure, produced in aerobic aqueous solutions ranging from pH 2 to 5, were determined in detail by the use of infrared external reflection spectroscopy, X-ray photoelectron spectroscopy and scanning electron microscopy. The most striking observation is that at pH 2 and 3 almost all oxidized iron is dissolved in solution, whereas at pH 4 and 5 the product of iron oxidation is deposited on the iron surface in the form of lepidocrocite, gamma-FeOOH. Detailed iron surface and solution analyses allow the proposition of the following overall oxidation reactions: [EQUATION: SEE TEXT]. At pH 2 and 3, only a very thin surface layer consisting of FeO and Fe(OH)2 with polymeric structure is observed on the iron surface. The amounts of these surface species remain almost constant (2-5 nm) from the first minutes to a few hours of reaction, if pH is kept constant. Nevertheless, with time the akaganeite-like, beta-FeOOH structure is also detected. At pH 4 and 5, the amount of lepidocrocite deposited on the iron surface increases with reaction time. Detailed quantitative evaluation of the lepidocrocite produced at pH 5 and its surface distribution on iron was performed based on the comparison of infrared spectroscopic data with spectral simulation results of assumed surface structures. At pH 4 and 5 and a temperature of 40-50 degrees C, in addition to a very large amount of lepidocrocite other oxy-hydroxide surface species such as goethite (alpha-FeOOH) and feroxyhite (delta-FeOOH), were identified. Addition of Cl- ions to solution at 10(-3) M concentration at pH 5 increases the oxidation rate of iron by about 50%, and lepidocrocite remains the only oxidation product. Similarly, an addition of Fe2+ ions to solution at pH 5 very strongly enhances lepidocrocite formation as well as its conductivity. The latter finding is important for the possible application of metallic iron as a catalyst in redox reactions, for example, for decomposition of difficult-to-biodegrade water pollutants.

Air↗

Mixed films of poly(n-hexyl isocyanate) and poly(vinyl acetate) at the air-water interface.

We study interfacial properties of rigid-rod-like poly(n-hexyl isocyanate) (PHIC), flexible poly(vinyl acetate) (PVAc), and mixed films of PHIC and PVAc spread at the air-water interface as a function of the molar fraction of PHIC by surface pressure measurements and fluorescence microscopy. From the plots of the experimental mean area of the mixed polymer films at a constant surface pressure as a function of the molar fraction of PHIC in the mixed films, the binary mixtures of PHIC/PVAc were concluded to be compatible at the air-water interface. This means that the hydrophobic hexyl group of PHIC takes a horizontal orientation to the air-water interface rather than a perpendicular one, leading to PHIC and PVAc having the same interfacial orientation. Compatibility of the binary mixtures of PHIC/PVAc at the air-water interface is also confirmed by their fluorescence microscopic images, since PHIC proves to be inhomogeneous and PVAc is homogeneous with the aid of a fluorescence probe, respectively.

Air↗