Search PubMed⌕ Search

PubMed · 11351490

Computer copings for partial coverage.

Abstract

Partial coverage posterior tooth preparations are very complex surfaces for computer surface digitization, computer design, and manufacture of ceramic copings. The aim of this study was therefore to determine whether the Computer Integrated Crown Reconstruction (Cicero) system was compatible with a proposed partial coverage preparation design and capable of producing ceramic copings. Posterior teeth were prepared for partial coverage copings with deep gingival chamfers in the proximal boxes and around the functional cusps (buccal of mandibular and lingual of maxillary posterior teeth). The nonfunctional cusps (lingual of mandibular and buccal of maxillary posterior teeth) were prepared with broad bevels following the inclined occlusal plane pattern. Optical impressions were taken of stone dies by means of a fast laser-line scanning method that measured the three-dimensional geometry of the partial coverage preparation. Computers digitized the images, and designed and produced the ceramic copings. The Cicero system digitized the partial coverage preparation surfaces precisely with a minor coefficient of variance of 0.2%. The accuracy of the surface digitization, the design, and the computer aided milling showed that the system was capable of producing partial coverage copings with a mean marginal gap of 74 microns. This value was obtained before optimizing the marginal fit by means of porcelain veneering. In summary, Cicero computer technology, i.e., surface digitization, coping design, and manufacture, was compatible with the described partial coverage preparations for posterior teeth.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Denissen, J van der Zel, J Reisig, S Vlaar, W de Ruiter, R van Waas. 1999. Computer copings for partial coverage.. https://pubmed.ncbi.nlm.nih.gov/11351490/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone.

OBJECTIVES: The purpose of this study was to compare the effects of the diameter, the length and the number of implants on stress distribution in the bone around the implants supporting three-unit fixed partial prostheses in the mandibular posterior edentulism. MATERIALS AND METHOD: A mandibular Kennedy II three-dimensional finite element model was constructed. Four fixed partial prostheses with two terminal implant supports of various lengths and diameters, and two fixed partial prostheses with three implant supports of various lengths were designed. In separate load cases, 400 N oblique, 200 N vertical, and 57 N horizontal forces were simulated. The tensile and the compressive stress values in the cortical bone around the collar of the implants and Von Mises stresses in the implants were evaluated. RESULTS: Although the change in the length of implants did not decrease the stress levels, lower tensile and compressive stress values were observed in the bone for wider implant placement configurations. Similar stress distributions and close stress levels were observed for two wider implant supports in comparison with the three-implant-supported fixed partial prostheses. CONCLUSION: With the use of two implants of 4.1-mm diameter and 10-mm length as terminal supports for three-unit fixed prostheses, the magnitude and the distribution of stresses in the cortical bone around the implant collar is within the normal physiological limits.

Bicuspid↗

Integrating posterior crowns with partial dentures.

This article outlines those considerations which are important in integrating posterior crowns with partial dentures. Planning the support and retention of the denture prior to crown construction will enhance patient treatment. Modification of the crown preparation to incorporate rest seats, retentive areas, guide planes and a planned path of insertion may be necessary.

Bicuspid↗

Root resorptions in upper first premolars after application of continuous torque moment. Intra-individual study.

MATERIAL AND METHOD: With the purpose of investigating the occurrence, localization and extension of possible root resorptions after fixed appliance treatment with a continuous torque force, 28 upper first premolars orthodontically indicated for extraction from 14 patients were analyzed by scanning electron microscopy. Tooth movement was carried out with continuous moments of different magnitudes (300 cNmm, and 600 cNmm), using a biomechanical model with superelastic wires (stainless steel-NiTi-SE), which was specially designed and individually calibrated. The teeth were divided into one control group with four premolars (non-moved) from two patients, and two experimental groups (300 cNmm and 600 cNmm respectively) with six patients each. Each group was distributed intra-individually as follows: the right first premolar of six patients was extracted after 1 week of movement, the left first premolars were removed after 2, 3 and 4 weeks. After extraction, teeth were fixed, treated with 2% sodium hypochlorite solution for 6 hours in order to remove the organic tissue components, dehydrated, and metal-coated in a Balzers SCD 050 apparatus. RESULTS: The analysis in a scanning electron microscope (Jeol 6100, at 10-15 kV) revealed many resorption lacunae in the root surface, mainly on the lingual side in the apical third of the roots. Resorption processes were also observed on the buccal root surface in the cervical third. All experimental teeth showed resorption areas. Teeth which had been moved for a longer time period and with a higher magnitude of applied moments showed a higher degree of root resorption in width as well as in depth. Higher magnitude of moments produced exposure of root dentine, evidencing pronounced root resorption.

Bicuspid↗