Search PubMed⌕ Search

PubMed · 11331959

Web-based tissue microarray image data analysis: initial validation testing through prostate cancer Gleason grading.

Abstract

Tissue microarray technology promises to enhance tissue-based molecular research by allowing improved conservation of tissue resources and experimental reagents, improved internal experimental control, and increased sample numbers per experiment. Organized, well-validated collection and analysis of the voluminous image data produced by tissue microarray technology is critical to maximize its value. Web-based technology for visual analysis and searchable storage of microarray image data could provide optimal flexibility for research groups in meeting this goal, but this approach has not been examined scientifically. Toward this goal, a prostate tissue microarray block containing 432 tissue cores (0.6 mm diameter) was constructed. Moderately compressed (200 kb).jpg images of each tissue spot were acquired and were saved using a naming convention developed by the SPORE Prostate Tissue Microarray Collaborative Group. Four hundred three tissue array spot images were uploaded into a database developed for this study and were converted to.fpx format to decrease Internet transmission times for high-resolution image data. In phase I of the image analysis portion of the study, testing and preliminary analysis of the Web technology was performed by 2 pathologists (M.A.R. and G.S.B.). In phase II, 2 pathologists (J.I.E. and T.M.W.) with no previous exposure to this technology and no knowledge of the structure of the study were presented a set of 130 sequential tissue spot images via the Web on their office computers. In phase III, the same pathologists were presented a set of 193 images, including all 130 from phase II and 63 others, with image presentation order randomized. With each zoomable tissue spot image, each pathologist was presented with a nested set of questions regarding overall interpretability of the image, presence or absence of cancer, and predominant and second most frequent Gleason grade. In phases II and III of the study, 319 of 323 (99%) image presentations using this Web technology were rated interpretable. Comparing the 2 pathologists' readings in phases II and III, Gleason grade determinations by each pathologist were identical in 179 of 221 (81%) determinations and were within 1 point of each other in 221 of 221 (100%) determinations, a performance rate similar to if not better than that previously reported for direct microscopic Gleason grading. Interobserver comparison of Gleason score determinations and intraobserver comparisons for Gleason grade and score also showed a pattern of uniformity similar to those reported in direct microscope-based Gleason grading studies. Interobserver (7.5%) and intraobserver (5% and 3%) variability in determining whether diagnosable cancer was present point out the existence of a "threshold effect" that has rarely been studied but may provide a basis for identification of features that are most amenable to improved diagnostic standardization. In summary, storage and analysis of tissue microarray spot images using Web-based technology is feasible and practical, and the quality of images obtained using the techniques described here appears adequate for most tissue-based pathology research applications. HUM PATHOL 32:417-427.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G S Bova, G Parmigiani, J I Epstein, T Wheeler, N R Mucci, M A Rubin. 2001. Web-based tissue microarray image data analysis: initial validation testing through prostate cancer Gleason grading.. https://doi.org/10.1053/hupa.2001.23517

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance of the FearID earprint identification system.

The Forensic Ear Identification (FearID) research project was started in order to study the strength of evidence of earprints found on crime scenes. For this purpose, a sample of earprints from 1229 donors over three countries was collected. From each donor three left and three right earprints were gathered. On the one hand, operators denoted contours of the earprints to facilitate segmentation of the images, on the other anthropological specialists denoted anatomically specific locations. On the basis of this, methods for automated classification were developed and used for training of a system that classifies pairs of prints as 'matching' or 'non-matching'. Comparing lab quality prints, the system has an equal error rate of 4%. Starting from a reference database containing two prints per ear, hitlist behaviour is such that in 90% of all query searches the best hit is in the top 0.1% of the list. The results become less favourable (equal error rate of 9%) for print/mark comparisons.

Databases, Factual↗

Normal limits of ejection fraction and volumes determined by gated SPECT in clinically normal patients without cardiac events: a study based on the J-ACCESS database.

PURPOSE: Quantitative gated single-photon emission computed tomography (SPECT) is known to have high accuracy and precision for measurement of the principal cardiac functional parameters. We hypothesised that normal values for EF and LV volumes may differ among nationalities, and that optimal threshold values specific to the study population are required. METHODS: Among 4,670 consecutively registered patients for a J-ACCESS (Japanese investigation regarding prognosis based on gated SPECT) study from 117 hospitals, a total of 268 (149 women, 119 men) were selected who had no baseline cardiac diseases and had experienced no cardiac events during the preceding 3-year period. A gated SPECT study was performed with 99mTc-tetrofosmin and analysed with Cedars Sinai Medical Center's quantitative gated SPECT (QGS) software. The results in respect of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV), and EDV, ESV and SV normalised by body surface area (EDVI, ESVI and SVI), were calculated and summarised to obtain normal limits. RESULTS: EF for women and men was 74 +/- 9% and 63 +/- 7%, respectively (p < 0.0001). EDV, ESV and SV were significantly smaller in women than in men. Based on multiple regressions for linear models, the primary and secondary predictors of EF, EDVI, ESVI were gender and age. By stepwise multiple regression analysis, a statistically significant third predictor for EDV, ESV, SV and SVI was body weight. No colinearity was found between age and body weight. Important factors for the studied Japanese population included a high incidence of small hearts in women and the relatively advanced age of the population (the mean age +/-SD was 64.1 +/- 10.0 years for women and 60.9 +/- 11.7 years for men). CONCLUSION: EF and volumes determined by gated SPECT with QGS were significantly affected by gender and age, with body weight as a third predictor for volumes. Moreover, the normal limits were so specific for the population studied that standards appropriate for the study in question should be utilised.

Databases, Factual↗