Search PubMed⌕ Search

PubMed · 1127862

Nephron functional heterogeneity in the postobstructive kidney.

Abstract

The purpose of this study was to determine the distribution of nephron filtration rates between superficial and juxtamedullary nephrons (S/J ratio) in kidneys studied immediately after relief of 24 hr total obstruction (acute) and after relief of prolonged partial obstruction (chronic). Injection of 14C-ferrocyanide and microdissection (modified Hanssen's technique) was used to provide an index of superficial and deep nephron glomerular filtration rate (GFR), and standard clearance determinations were done. In normal kidneys S/J ratio of 14C content (nephron GFR) was 0.73 plus or minus 0.03, a value similar to those obtained by other workers. After relief of acute obstruction, nephron GFR was too low for accurate measurement in 22% of superficial and 13% of deep nephrons. The mean S/J ratio of 14C content was similar to control, being 0.67 plus or minus 0.07, with only three of seven kidney showing loss of the normal S/J ratio. Since redistribution of nephron GFR was an inconsistent finding, while marked diuresis and natriuresis occurred in all rats, it appears that redistribution of nephron GFR is not an important factor in the phenomenon of postobstructive diuresis. After relief of chronic obstruction, diuresis and natriuresis were less marked but the mean S/J ratio of 14C content was 0.95 plus or minus 0.11, and in the majority of kidneys (six of eight), there was loss of distinction between superficial and deep nephron GFR. This redistribution of nephron function after relief of chronic, rather than acute, obstruction may be due to the more severe structural damage to the renal medulla of such kidneys and, although not responsible for postobstructive diuresis, it may be important in the diminished capacity of the chronically hydronephrotic kidney to conserve salt and water.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Wilson. 1975. Nephron functional heterogeneity in the postobstructive kidney.. https://doi.org/10.1038/ki.1975.3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗