Search PubMed⌕ Search

PubMed · 11257530

Data registration and selective single-molecule analysis using multi-parameter fluorescence detection.

Abstract

A general strategy to identify and quantify sample molecules in dilute solution employing a new spectroscopic method for data registration and specific burst analysis denoted as multi-parameter fluorescence detection (MFD) was recently developed. While keeping the experimental advantage of monitoring single molecules diffusing through the microscopic open volume element of a confocal epi-illuminated set-up as in experiments of fluorescence correlation spectroscopy, MFD uses pulsed excitation and time-correlated single-photon counting to simultaneously monitor the evolution of the four-dimensional fluorescence information (intensity, F; lifetime, tau; anisotropy, r; and spectral range, lambda(r)) in real time and allows for exclusion of extraneous events for subsequent analysis. In this review, the versatility of this technique in confocal fluorescence spectroscopy will be presented by identifying freely diffusing single dyes via their characteristic fluorescence properties in homogenous assays, resulting in significantly reduced misclassification probabilities. Major improvements in background suppression are demonstrated by time-gated autocorrelation analysis of fluorescence intensity traces extracted from MFD data. Finally, applications of MFD to real-time conformational dynamics studies of fluorescence labeled oligonucleotides will be presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Eggeling, S Berger, L Brand, J R Fries, J Schaffer, A Volkmer, C A Seidel. 2001-04-13. Data registration and selective single-molecule analysis using multi-parameter fluorescence detection.. https://doi.org/10.1016/s0168-1656(00)00412-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

IMPACT OF FLUORESCENT DYES ON MUTATIONS IN NEXT GENERATION SEQUENCING LIBRARY GENERATION.

DNA labelling fluorescent dyes such as ethidium bromide have long been considered to be highly mutagenic during DNA replication. While recent studies have pushed back on this narrative, the intercalative nature of these dyes continues to raise the possibility that these dyes can induce mutations. The iconPCR instrument by n6tec uses fluorescent dyes to measure amplification in real time and to adjust cycling conditions. However, since this use of qPCR is preparative and not analytical, mutations introduced by fluorescent dyes would be propagated into the sequencing reaction. To address the impact of these dyes on downstream analyses, we have performed routine mutation calling as well as mutational signature analysis on samples amplified using the iconPCR in the presence of either SYBR or EvaGreen. Sequence analysis revealed very minimal impacts of dyes on the reactions, largely within the noise regimen with only subtle changes in mutation rates seen. Mutational signature analysis was unable to identify any key signatures assignable to the dyes in either substitutions or indel domains. The mutational impact of intercalating dyes during fluorescence-guided amplification is therefore minimal and can be disregarded in all but the most sensitive NGS applications.

Fluorescent Dyes↗

Synthesis of labelled PNA oligomers by a post-synthetic modification approach.

The preparation of t-butoxycarbonyl (Boc)-protected O(4)-(o-nitrophenyl) thymine peptide nucleic acid (PNA) monomer is described. This PNA monomer was incorporated into PNA oligomer sequences. The post-synthetic modification of the oligomers to yield fluorescently-labelled PNA oligomers was studied before and after the removal of the protecting groups. In both cases, the desired fluorescently-labelled PNA oligomer was obtained in good yields.

Fluorescent Dyes↗