Search PubMedSearch

PubMed · 1117920

Letter: Decrease of HB-s Ag titers after repeated freezing and thawing.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Schlaak, H Lehmann, H Schläfer. 1975-04-24. Letter: Decrease of HB-s Ag titers after repeated freezing and thawing.. https://doi.org/10.1056/nejm197504242921717

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Materials surveillance, a surveillance performed on the use of medical devices].

One of the missions of the Agence Française due Sang was to set up a haemovigilance system based on a national network of surveillance and alert, for the whole blood chain from blood collection to receivers' follow-up. This system is now operational and contributes with efficacy to the safety of blood transfusions (see: A quoi sert l'hémovigilance? Transfus Clin Biol 1998; 5: 415-21.). The French law No. 98-535 dated July 1st 1998, whose enforcement orders were published in March 1999, is the legal foundation of the system. In this article the national and regional structures of the national system of sanitary safety are described, and the main guidelines of material vigilance, the last element of this system, is presented.

Blood Preservation

Differential leucocyte subpopulation analysis of leucodepleted red cell products.

Donor leucocytes are responsible for many adverse transfusion effects. Clinical reactions may be attributed to specific leucocyte subsets. In this study leucocyte subpopulations were identified and quantified pre- and post-leucodepletion by integral filtration using novel Optipac(R) configurations incorporating either WBF-1 (Pall Medsep) or RS2000 (Asahi) whole blood filters. Leucocytes were analysed by flow cytometry using direct, four-colour, membrane immunofluorescence with monoclonal antibodies specific for CD 3, 14, 16, 19 and 45. Filtration reduced the leucocyte load by 3-4 log10, consistently giving products with < 2 cells microL-1. Subset distributions were also affected with the proportion of neutrophils and monocytes increased and the lymphocyte/monocyte ratio inverted. These effects were independent of the preprocessing hold conditions, filter used and buffy coat (BC) removal. All filtered red cell products contained 75-80% neutrophils, 16-20% monocytes and 2-7% lymphocytes. Results presented here demonstrate that whole blood filtration, and BC removal, significantly reduce the content and substantially alter the subpopulation distribution of the donor leucocytes remaining in leucodepleted red cell products.

Blood Preservation

Transfusion of platelet concentrates from pooled buffy-coats: comparison of bedside vs. prestorage leukofiltration.

Prestorage leucocyte filtration of platelet concentrates (PC) has been considered to be superior to bedside filtration with regard to the incidence of nonhaemolytic transfusion reactions (NHTR) or HLA-alloimmunization. It is currently a matter of debate whether prestorage leucocyte filtration has an impact on the storability of platelets and on the transfusion results of PC. In a clinical retrospective study we investigated the transfusion results of PC from pooled buffy-coats (PC-BC) in haematological patients without known refractoriness to platelets, and compared bedside filtration (n = 228/36 patients) vs. prestorage filtration (n = 271/25 patients). Leukocyte and platelet content of the PC, duration of storage, platelet count of the patient before transfusion and 20 h after transfusion were determined and platelet increment and corrected count increment (CCI) 20 h after transfusion were calculated. The mean leucocyte content of the bedside filtered PC was 66 +/- 50 x 106 and < 0.1 x 106 for the prestorage filtered PC (P < 0.001). Mean platelet content of the PC (2.6 x 1011 vs. 2.7 x 1011) and the duration of PC storage (2.7 vs. 2.6 days) were almost identical in both groups. The platelet increment after 20 h (14.6 x 109 L-1 vs. 14.9 x 109 L-1) was equal for both groups, but CCI values were significantly higher for the bedside filtered PC (14.1 +/- 9.5 vs. 11.4 +/- 6.8) (P = 0.008). Correlation with the storage time revealed that CCI levels were higher for bedside filtered PC after short-term storage (< 36 h) (P = 0.014), but declined more rapidly compared with prestorage filtered PC. A patient-based analysis including fewer cases revealed superior but nonsignificant results for bedside filtration. In conclusion, bedside filtered PC-BC resulted in better CCI results after short-term storage, but values equalized with prestorage filtered PC-BC after longer storage intervals. Prestorage-leucocyte filtration did not improve platelet recovery in vivo, but CCI values decreased only moderately throughout storage. Both preparations showed excellent transfusion results even after a 5-day storage interval.

Blood Preservation