Search PubMed⌕ Search

PubMed · 11127915

Experimental evolution recapitulates natural evolution.

Abstract

Genomes of the closely related bacteriophages phiX174 and S13 are 5386 bases long and differ at 114 nucleotides, affecting 28 amino acids. Both parental phages were adapted to laboratory culture conditions in replicate lineages and analysed for nucleotide changes that accumulated experimentally Of the 126 experimental substitutions, 90% encoded amino-acid changes, and 62% of the substitutions occurred in parallel in more than one experimental line. Furthermore, missense changes at 12 of the experimental sites were at residues differing between the parental phages; in ten cases the phiX174 experimental lineages were convergent with the S13 parent, or vice versa, at both the nucleotide and amino-acid levels. Convergence at a site was even obtained in both directions in three cases. These results point to a limited number of pathways taken during evolution in these viruses, and also raise the possibility that much of the amino-acid variation in the natural evolution of these viruses has been selected.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H A Wichman, L A Scott, C D Yarber, J J Bull. 2000-11-29. Experimental evolution recapitulates natural evolution.. https://doi.org/10.1098/rstb.2000.0731

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Membrane-mediated ultrafast restriction digestion and subsequent rapid gel microchip electrophoresis of DNA.

Ultrafast, membrane-mediated restriction digestion of DNA molecules followed by rapid gel microchip electrophoresis of the resulting fragments is described. Combination of restriction endonuclease digestion on small pore-size microfibrous membranes with sample loading and electrophoresis analysis in a multilane (up to 96) format resulted in very fast restriction digest based microscale DNA analysis. Complete digestion of several nanogram target DNA was accomplished on the microporous membrane at room temperature just in a few minutes with a single or a combination of various restriction enzymes, using only submicroliter quantities of samples and reagents. The reaction mixture containing membrane also served as sample loading device for the subsequent gel microchip electrophoresis based analysis. This work establishes methods for high-speed, high-throughput DNA analysis, featuring extremely low sample and reagent consumption, and fast restriction digestion in combination with sample loading and rapid gel microchip analysis of the resulting fragments. The entire restriction digestion, sample loading and electrophoresis analysis process required less than 20 min.

Bacteriophage phi X 174↗

Integrity of powdered and powder-free latex examination gloves.

OBJECTIVES: The difference in permeability between one brand of powdered and another of powder-free latex examination gloves was evaluated to determine leak rates. METHODS: Thirty-one of each type of glove were tested for each of three different conditions: usage by dental personnel (1) for 15 minutes or longer, (2) for less than 15 minutes, and (3) directly from the manufacturer's packaging (zero usage time). Each glove was evaluated in the fingers and the palm. The phiX-174 viral solution in the glove was allowed to penetrate for 15 minutes. Powder (cornstarch) was subsequently added to 20 powder-free gloves, and 15 of these were pierced with a 30-gauge needle. RESULTS: Powdered gloves showed no leakage rates. Because of this, 30-, 27-, and 25-gauge needles were used to pierce five gloves each. One glove with 27- and 25-gauge needle holes showed leakage. Leakage rates for powder-free gloves: 45.1 percent for more than 15 minutes of use, 25.8 percent for less than 15 minutes of use, and 16.1 percent for zero minutes of use. Two of the 20 pierced and one of the five unpierced powder-free gloves with added cornstarch leaked. CONCLUSION: Significant differences in leak results between powdered and powder-free gloves suggest further study is needed.

Bacteriophage phi X 174↗

PCR-based method for detecting viral penetration of medical exam gloves.

The test approved by the U.S. Food and Drug Administration for assessment of the barrier quality of medical exam gloves includes visual inspection and a water leak test. Neither method tests directly the ability of gloves to prevent penetration by microorganisms. Methods that use microorganisms (viruses and bacteria) to test gloves have been developed but require classical culturing of the organism to detect it. We have developed a PCR assay for bacteriophage phiX174 that allows the rapid detection of penetration of gloves by this virus. The method is suitable for use with both latex and synthetic gloves. The presence of glove powder on either latex or synthetic gloves had no effect on the ability of the PCR assay to detect bacteriophage DNA. The assay is rapid, sensitive, and inexpensive; requires only small sample volumes; and can be automated.

Bacteriophage phi X 174↗