FDG imaging.

Abstract

F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) imaging is being increasingly utilized in the detection of malignancy and in following the effects of therapy. FDG-PET imaging has been demonstrated to be accurate in the diagnosis of several malignancies including lung cancer, lymphoma, recurrent colorectal cancer, and recurrent melanoma. The initial studies evaluating FDG-PET in determining the effect of therapy reveal promising results. The clinical images are interpreted subjectively like other clinical nuclear medicine imaging studies. Semiquantitative indices such as the standardized uptake value may be used for research purposes to provide a quantitative parameter from the study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R E Coleman. 2000. FDG imaging.. https://doi.org/10.1016/s0969-8051(00)00139-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Impact of fluorine-18 fluorodeoxyglucose positron emission tomography on patient management: first year's experience in a clinical center.

PURPOSE: To measure the impact of whole-body fluorodeoxyglucose (FDG) positron emission tomography (PET) on patient management during its first year of use in a community hospital. MATERIALS AND METHODS: First-year FDG-PET impact was determined from 463 referring physicians' evaluations of their patients' PET imaging results using two surveys. Survey 1 was given to all physicians referring patients to PET to discover whether PET changed patient management or had decision-making value in the patient's clinical algorithm. Survey 2 was given to one surgeon and one pulmonologist after therapy to determine how PET affected the surgical, chemotherapeutic, and/or radiotherapeutic treatment for the 53 cancer patients they referred. RESULTS: The 463 responses to survey 1 described 23 different PET indications. Lung (40%), head and neck (18%), and colorectal cancers (11%) were the three leading causes of referral. PET changed patient management/therapy in 45% of all patients referred and had inferential/decision-making value in another 44%. Overall, PET had some type of positive influence in 412 (89%) of the patients. Survey 2 provided a more detailed assessment of 53 referrals from two specialists. PET positively affected surgery in 31 patients (58%), prompted the addition of chemotherapy or radiation therapy in nine patients (17%), and eliminated chemotherapy or radiation therapy in four cases (8%). Overall, PET affected patient management/therapy in 70% of the cases and had some decision-making value in another 26%, for a combined PET impact on patient management of 96%. CONCLUSION: FDG-PET can be valuable for physicians in clinical practice. Its sensitivity and specificity in metabolic imaging, when combined with complementary anatomic imaging techniques, contribute significantly to the clinical treatment of cancer patients. In addition, the high accuracy of FDG-PET makes it a cost-effective radiologic procedure in the work-up of all suspected and/or recurrent cancer patients. Further research is needed to link this demonstrated impact on patient management to cost-effectiveness.

Fluorodeoxyglucose F18↗

Performance assessment of O-18 water purifier.

In the synthesis of 18F-FDG by the nucleophilic substitution method, 18O-H2O is usually used as target water. The target water should be recovered after synthesis and reused, because it is expensive, but recovered water contains impurities such as organic substances, and it must be purified before reuse. For this reason Sumitomo Heavy Industries, Ltd. developed an O-18 water purifier for elimination of organic substances in recovered water. This instrument consists of a UV irradiation unit and low-temperature distillation unit. Our institution had an opportunity to test use this instrument and evaluated its performance. The concentrations of organic substances after UV irradiation was greatly reduced, and recovery efficiency after distillation by the low-temperature distillation unit was very satisfactory at 99.3 +/- 0.5%. Furthermore, the yield of 18F-FDG from 18O-H20 purified with this instrument was sufficient for the clinical use.

Fluorodeoxyglucose F18↗