Search PubMed⌕ Search

PubMed · 11021029

Piercing dangers.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Boistelle. 2000-08-12. Piercing dangers.. https://pubmed.ncbi.nlm.nih.gov/11021029/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone.

OBJECTIVES: The purpose of this study was to compare the effects of the diameter, the length and the number of implants on stress distribution in the bone around the implants supporting three-unit fixed partial prostheses in the mandibular posterior edentulism. MATERIALS AND METHOD: A mandibular Kennedy II three-dimensional finite element model was constructed. Four fixed partial prostheses with two terminal implant supports of various lengths and diameters, and two fixed partial prostheses with three implant supports of various lengths were designed. In separate load cases, 400 N oblique, 200 N vertical, and 57 N horizontal forces were simulated. The tensile and the compressive stress values in the cortical bone around the collar of the implants and Von Mises stresses in the implants were evaluated. RESULTS: Although the change in the length of implants did not decrease the stress levels, lower tensile and compressive stress values were observed in the bone for wider implant placement configurations. Similar stress distributions and close stress levels were observed for two wider implant supports in comparison with the three-implant-supported fixed partial prostheses. CONCLUSION: With the use of two implants of 4.1-mm diameter and 10-mm length as terminal supports for three-unit fixed prostheses, the magnitude and the distribution of stresses in the cortical bone around the implant collar is within the normal physiological limits.

Bicuspid↗

A calculation of stress distribution in metal-porcelain crowns by using three-dimensional finite element method.

The objective of this study was to calculate stress distribution in a maxillary second premolar tooth which occurred by the mastication force. The tooth model was crowned with Au-Pd alloy, Ni-Cr alloy and porcelain. A load of 450 N, at an angle of 45 degrees to the longitudinal axis was applied on the occlusal margin of the crown tooth. The tooth was assumed isotropic, homogenous, elastic and unsymmetrical. This numerical study was carried out using three-dimensional finite element models and calculation programs were prepared by the authors using FORTRAN 77. The distribution of compressive, tensile and shear stress were plotted for the dentine, dentine-metal and metal-porcelain interfaces. The highest stress values were observed when Ni-Cr alloy and porcelain was used.

Bicuspid↗