Search PubMed⌕ Search

PubMed · 10998629

Low-resolution phase extension using wavelet analysis.

Abstract

A method to extend low-resolution phases is presented which uses histogram matching not only of the electron density, but also of histograms obtained from the different levels of detail provided by the wavelet transform of the electron density. Statistical values for the wavelet coefficients can be predicted and depend only on the resolution and solvent content. Therefore, new details can be added to an electron-density map by matching the values of the wavelet coefficients to those predicted for an increased resolution. The positions of the new details are also guided by the diffraction pattern. In this way, the resolution can be increased gradually; on a number of trial structures of different size, solvent percentage and space group, it has been possible to extend the phasing from 10 A to around 6-7 A.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Main, J Wilson. 2000. Low-resolution phase extension using wavelet analysis.. https://doi.org/10.1107/s0907444900010283

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Technical note: reconstructing dose distributions from manually planned electron boosts in breast radiotherapy.

PURPOSE: In breast radiotherapy, delivery of manually-calculated electron boosts limits retrospective dose-response analyses as dose distribution is unavailable. This work evaluates the feasibility of reconstructing dose distributions from manually planned electron boosts in breast-conserving radiotherapy. METHODS: Only 72 out of 198 breast cancer patients had complete stored dose distributions from sequential electron boosts in the REQUITE study. Arbitrary data from 70/72 patients were used to develop and validate dose reconstruction method. Twenty patients were used to determine optimal parameters for Monte-Carlo-based (MC) electron dose reconstruction on RayStation (v.11B-R), considering CT-calibration curve, MC-history number, andcalculation grid resolution. Remaining 50 patients were used to quantify dose reconstruction accuracy. The similarity between reconstructed and stored dose was evaluated using 3D-gamma index and dosimetric parameters extracted from breast and tumour bed contours. Dose difference location was evaluated using dose-location histogram. RESULTS: Calculation grid resolution significantly impacted electron dose distribution (p&#xa0;<&#xa0;0.01), where the finest grid (0.15&#xa0;cm) showed highest similarity to stored doses. CT-calibration curve and MC-history number had a negligible influence on dose reconstruction. Dosimetric difference between reconstructed and stored doses was&#xa0;<&#xa0;1&#xa0;Gy for breast and tumour bed. Reconstructed dose was achieved&#xa0;>&#xa0;90% gamma passing rate in the validation set. However, around 2.5&#xa0;Gy dose differences were observed at the skin and tissue interface regions. CONCLUSIONS: Retrospective electron boost dose reconstruction is feasible with acceptable accuracy, and could increase data completeness in large cohort studies. Caution is advised when assessing dose near tissue interface and further validation is needed outside the REQUITE dataset.

Electrons↗

Structure-property relationships in dendritic encapsulation.

Several molecular structure-property relationships are presented and compared to illustrate our current understanding of macromolecular encapsulation using dendrimers. Specifically, the effect that dendrimer architectures have on encapsulating photoactive and redox-active units fixed at the molecular core is considered.

Electrons↗

Interactions and reactions of monolayers and Langmuir-Blodgett multilayers with compounds in the bulk phase.

Studies performed on the interactions and reactions of compounds in the bidimensional state, essentially in monolayers and Langmuir-Blodgett multilayers, with substances in the aqueous subphase are reported. More precisely, the following is illustrated: (i) interactions between acid amphiphiles and prevalently bivalent ions placed in the aqueous support and between compounds capable of functioning like ion carriers in monolayers and ions in the subphase, in order to build mimetic membranes capable of selective ion transport; and the complexation of amphiphiles in monolayer with ions in the bulk liquid phase, in order to build chemical sensors to ions; (ii) the reactions of photoinduced electron transfer between a partner in mono- or multimolecular films and a partner in the subphase, which may determine the fundamental parameters and the differences with the same reactions in the bulk phase; and (iii) the reactions of enzymatic hydrolysis between the monolayer of a glyceride, which constitutes the reaction support, and the enzyme in the liquid bulk phase, which constitutes the subphase. The mechanism of the reactions and its inhibition are clarified. To conclude, possible future developments connected with the areas studied are examined.

Electrons↗