Abstract

An index to measure the change in hip flexor function after hip surgery was developed in the Motion Analysis Laboratory at Gillette Children's Specialty Healthcare (GCSH). The hip flexor index (HFI) utilizes principal component analysis applied to five kinematic and kinetic variables collected during normal acquisition of gait data. A single index number is derived that describes accurately the overall hip function. Initial clinical validation was carried out using a data set of 23 normal controls and six patients with a diagnosis of cerebral palsy. The patients were all independent ambulators who had undergone orthopedic hip surgery. The controls were used to establish patterns of interdependency between selected gait parameters and form a basis for the index number. The HFI based surgical outcome was compared to the subjective rating of six clinicians. The clinicians were versed in gait analysis and were blinded to the HFI based outcome. The HFI measure of post-operative change in hip function was found to correspond well with the subjective clinical evaluation. A valid tool such as the HFI can be used to objectify clinical impressions of change in hip function, and can thereby assist researchers with statistical and outcome analysis of interdependent and redundant gait variables.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Schwartz, T F Novacheck, J Trost. 2000. A tool for quantifying hip flexor function during gait.. https://doi.org/10.1016/s0966-6362(00)00064-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The fertilization dance: a mechanical view of the egg rotation during the initial spermatozoa-ovum interaction.

The motion of the ovum and the spermatozoa toward each other in the oviduct culminates in a meeting that ultimately results in fertilization. This encounter is characterized by a slow rotation of the sperms-egg cluster while the sperms attempt a penetration. The mysterious rotation was observed in vivo and in vitro for homologous and heterologous systems. It lacks a satisfactory biological explanation while it seems to be correlated with the efficiency of fertilization. A simple bio-mechanical model presented here predicts that the slow rotation of the sperms-egg cluster is a natural consequence of the encounter in most cases. A linear stability analysis of the system suggests a quantitative explanation of the rotation causes, its intensity and its direction. The entire encounter seems as a micro-scale process of courting of the ovum by the spermatozoa, which is expressed as circular dance.

Biomechanical Phenomena↗

Collagen and bone viscoelasticity: a dynamic mechanical analysis.

The purpose of this study was to explore the effects of changes in Type I collagen on the viscoelasticity of bone. Bone coupons were heated at either 100 or 200 degrees C to induce the thermal denaturation of Type I collagen. Half of these specimens were rehydrated after heat treatment; the other half were tested in a dry condition. The degree of denatured collagen (DC%) was analyzed by a selective digestion technique with the use of alpha-chymotrypsin. Isothermal (37 degrees C) and variable temperature tests (scans from 35 to 200 degrees C) were performed with the use of a dynamic mechanical analyzer to evaluate changes in bone viscoelastic properties as a function of collagen damage, specifically, changes in the loss factor (tan delta) and storage modulus (E') were assessed. Significant collagen denaturation occurred only when bone was heated at 200 degrees C irrespective of the hydration condition. Also, DC% did not show a significant effect on tan delta. However, higher values of tan delta were observed in wet samples compared to dry specimens. The temperature-scan tests revealed that the hydration condition, but not DC%, significantly affected the behavior of tan delta. However, E' was not strongly influenced either by DC% or by water content. These results suggest that at a constant frequency the denaturation of collagen triple-helical molecules may have few effects on the viscoelasticity of bone, but moisture may play a prominent role in determining this property.

Biomechanical Phenomena↗

The fundamental problem of myoskeletal inverse dynamics and its implications.

The validity of current inverse dynamics models utilized for motion analysis is investigated. It is shown that observables generated by the real biosystem, such as ground reaction forces, are incompatible with comparable responses of skeletodynamical inverse models currently in use. This implies that results obtained with such models are erroneous to varying degrees while a quantification of these errors is difficult or impossible. This phenomenon is termed the fundamental myoskeletal inverse dynamics problem. A model fidelity indicator is proposed which, for a specific inverse dynamics model applied to a particular motion, provides a dimensionless numerical measure for the replicative validity of that model and the fidelity of its input data. A practical example demonstrates the usefulness of this indicator. It is suggested that the development of structurally sufficiently complex and biologically more realistic skeletomechanical models as well as substantial error reductions in data measuring and processing procedures will be necessary to improve the accuracy of inverse dynamics model computations.

Biomechanical Phenomena↗