Single cell sorting and cloning.

Abstract

Cell sorters now allow the selection of cells and other bodies according to a range of quite diverse criteria. The additional refinement that allows the sorting of individual cells based on these criteria has seen application in many fields of research. Single cells may be sorted for microscopy, for culture and for genetic analysis by way of single cell PCR (polymerase chain reaction). In practical terms, in the setting up of an instrument for single cell sorting, there are additional requirements to ensure that each detected event is indeed a single cell or body, that this cell can be reliably sorted via saline droplet, separate from its fellow travelers, that the aiming of the droplet deflection is sufficiently precise to find the target vessel and that the cell will be undamaged on arrival. Among the diverse reported applications of the technique, two fields which have benefited greatly are lymphocyte development and haemopoiesis. In the former case, the analysis of gene rearrangements in lymphocytes, both in the pre- and post-antigenic phases of development, has been enabled by the combined technologies of single cell sorting and PCR. It is argued that such experiments could not have been done without that partnership. In a similar way, the single cell sorting technique has been found to be the perfect way to demonstrate precursor/progeny relationships between haemopoietic cells and, further, to demonstrate rigorously the effects of particular cytokines on the haemopoietic system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F L Battye, A Light, D M Tarlinton. 2000-09-21. Single cell sorting and cloning.. https://doi.org/10.1016/s0022-1759(00)00225-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Relative frequency of malaria pigment-carrying monocytes of nonimmune and semi-immune patients from flow cytometric depolarized side scatter.

BACKGROUND: Recently, it was observed that malaria can be detected by performing automated complete blood count analysis including depolarization measurement of scattered laser light. To explain large discrepancies in sensitivity and specificity observed in semi-immune and nonimmune malaria patients, we determined the relative frequencies of malaria pigment-carrying monocytes (PCM) by flow cytometric measurements combined with rare event analysis. METHODS: An experimental cell-sorting unit utilizing argon, krypton, and helium-neon lasers measured the relative frequencies of leukocytes of malaria patients. Single white blood cells showing high intensity in their depolarized side scatter were sorted for subsequent microscopic analysis. RESULTS: From microscopic inspection of sorted cells, we identified malaria PCM as a distinct cluster in scatter diagrams that is well separated from normal leukocytes. For nonimmune patients, the average relative frequency of PCM is 1.5 x 10(-4) (median), for semi-immune patients 8.8 x 10(-4), and for malaria-negative persons 4.4 x 10(-6). Results derived from depolarized side scatter at 488, 633, or 647 nm agree well. Furthermore, malaria pigment-carrying neutrophilic granulocytes were identified microscopically after sorting. We discuss briefly how pigment-carrying neutrophils might be differentiated from normal leukocytes and PCM by using flow cytometry and measuring depolarized side scatter at two wavelengths. CONCLUSION: Our results confirm the feasibility of malaria detection by flow cytometry for semi-immune patients and extend malaria detection to nonimmune patients with low frequencies of PCM. High sensitivity and specificity for malaria detection were obtained.

Cell Separation↗