[Guywire dentures].

Abstract

Analyzes possible complications and shortcomings of traditional prosthetic treatments. Presents a new approach to prosthetic treatment and describes the general design of guy dentures. Describes in brief the biomechanics, methods of making guy dentures, and discusses their advantages in comparison with the traditional dentures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A N Riakhovskiĭ. 2000. [Guywire dentures].. https://pubmed.ncbi.nlm.nih.gov/10961115/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional optical high-resolution profiler with a large observation field: foot arch behavior under low static charge studies.

Our aim is to describe a method for detecting small deformations from a three-dimensional (3D) shape of large lateral dimensions. For this purpose the measurement method is based on the simultaneous utilization of several 3D optical systems and the phase-shifting technique. In this way, the following problems appear: optical distortion due to the large field observed, nonlinear phase-to-height conversion, conversion of image coordinates into object coordinates for each 3D optical system, and coordinate unification of all optical systems. The resolution is 50 microm with a field of view of 320 mm x 150 mm. We used this system to study the 3D human foot arch deformation under low loads in vivo. First results indicate the hysteresis behavior of the human foot under a low load (50 to 450 N).

Biomechanical Phenomena↗

A study of the mechanical stability of scoliosis constructs using variable numbers of sublaminar wires.

Sublaminar wiring with posterior instrumentation is one of the methods used when long fusions involving 10-12 thoracolumbar levels are required. Classically, wires are used at every consecutive level to make the construct as rigid as possible, although complications like dural tears, cerebrospinal fluid leak, and neurological deficit have been reported during their passage. We compared the mechanical stability under torsional strain of five specimens of each of three construct designs, by static and fatigue testing, using an electro-servo-hydraulic testing machine. In construct A, a contoured Hartshill rectangle was used from T2 to L2, with sublaminar wires passed at every level. In construct B, the Hartshill rectangle was wired to the spine at every alternate level. In construct C, every alternate level was wired except at the proximal end, where two consecutive levels were wired. Industrially fabricated spine models were used to prepare these constructs. The intervertebral motion within the construct was measured using the Fastrak magnetic field sensor device. On static testing, no statistically significant difference was found in the rotational displacement of the three construct designs. On fatigue testing, all samples of construct B consistently failed, with breakage of the wire at the most proximal level on the left side. But on adding additional wires to the next level (construct C), all five samples withstood fatigue testing at 300 N load to three million cycles. We conclude that wiring alternate levels instead of every level does not compromise the stability of the construct, provided that the most proximal two levels are consecutively wired. This practice would minimise the risk of dural tears and cord damage during wire passage and reduce surgical time, not to mention the economic benefits.

Biomechanical Phenomena↗

Clinical, echocardiographic, and biomechanical differences in mitral valve prolapse affecting one or both leaflets.

Mitral valve prolapse (MVP) is the most common cause of severe mitral regurgitation necessitating surgical correction. Unileaflet prolapse (ULP), usually involving the posterior leaflet, is more common than bileaflet prolapse (BLP), which is more difficult to repair. Little is known about clinical, echocardiographic, and biomechanical differences between ULP and BLP. In this study, biomechanical testing was performed on mitral valve leaflets and chordae obtained at operation for severe mitral regurgitation. Preoperative clinical characteristics and echocardiographic measurements were obtained on surgical patients (ULP = 88, BLP = 37). Men outnumbered women by a factor of 4:1 in ULP, and by 3:1 in BLP. Patients with BLP were younger (53.2 +/- 1.7 vs 59.5 +/- 1.1 years) than those with ULP, and this difference was greater in women (48.9 +/- 2.5 vs 62.9 +/- 2.2 years). BLP patients were less likely to be hypertensive, and more likely to undergo valve replacement rather than repair. Echocardiography showed that BLP leaflets were longer and thicker than ULP leaflets. The severity of mitral regurgitation was similar in both groups, although ULP patients had a much higher incidence of flail leaflets (45% vs 5% in BLP). Mechanical strength of chordae was greater in BLP than in ULP, although leaflet strength was similar. The increased chordal strength in BLP may be responsible for less flail. In patients with MVP and severe mitral regurgitation requiring surgery, ULP and BLP are distinct entities with substantial differences in the population affected, in echocardiographic manifestations including prevalence of flail, in chordal mechanics, and in the likelihood of surgical repair.

Biomechanical Phenomena↗