Search PubMed⌕ Search

PubMed · 10937361

Modelling transthoracic defibrillation waveforms.

Abstract

Recent investigations connected with implantable defibrillators yielded new data on heart electrophysiology, resulting in reassessment of existing and advancing of new types of electrical impulses. Different electrical equivalent circuits were proposed for modelling intracardiac and transthoracic defibrillation pulse waveforms, comprising generator, electrode interface and tissue resistances. We attempted modelling of the transmembrane voltage Vm time course, induced by different applied voltage Vs waveforms, taking into account only the shapes and the relative Vs and Vm amplitudes. The excitable cell membrane impedance Zm was modelled with higher resistance and lower capacitance, so that a shunting effect on the generator and tissue resistances was avoided. The result was a very simple equivalent circuit. We proposed criteria for efficient defibrillation pulse waveforms yielding a straightforward approach to model existing and new pulses and to assess their efficiency.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Krasteva, A Cansell, I Daskalov. Modelling transthoracic defibrillation waveforms.. https://doi.org/10.1080/030919000409320

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗