Search PubMed⌕ Search

PubMed · 10912347

An alpha modulation index for electroencephalographic studies using complex demodulation.

Abstract

An automated technique for measuring the relative amount of amplitude modulation of electroencephalographic (EEG) alpha activity is developed to increase the number of existing tools for differentiating the various types of alpha activity. EEG data collected from 12 normal males is used to characterize alpha modulation frequency characteristics. From these findings, a complex demodulation method is constructed to extract the amplitude modulation envelope of alpha activity from an epoch of EEG data while disregarding both continuous amplitude alpha activity and activity outside the alpha band. A threshold technique is then used to determine the relative amount of modulation contained within the data epoch. This metric is termed the alpha modulation index (AMI). Good correlation (R2 = 0.86) is found when automated scoring results are compared with manual scoring of physiologic EEG alpha modulation. The flexibility of this technique makes it easily adaptable to other EEG frequency bands and applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Schroeder, R E Barr. 2000. An alpha modulation index for electroencephalographic studies using complex demodulation.. https://doi.org/10.1007/bf02347051

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A Kalman filter based methodology for EEG spike enhancement.

In this work, we present a methodology for spike enhancement in electroencephalographic (EEG) recordings. Our approach takes advantage of the non-stationarity nature of the EEG signal using a time-varying autoregressive model. The time-varying coefficients of autoregressive model are estimated using the Kalman filter. The results show considerable improvement in signal-to-noise ratio and significant reduction of the number of false positives.

Electroencephalography↗

Visual evoked potential in the newborn: does it have predictive value?

We reviewed studies on the predictive value of visual evoked potentials (VEPs) in the newborn. VEPs demonstrated a good correlation with neurodevelopmental outcome in full-term infants with birth asphyxia. However, their prognostic value in preterm infants is controversial. In preterm infants, most studies showed high specificities for neurodevelopmental outcome, but some studies demonstrated lower sensitivities.

Electroencephalography↗