Search PubMed⌕ Search

PubMed · 10875355

Regularized matched-mode processing for source localization.

Abstract

This paper develops a new approach to matched-mode processing (MMP) for ocean acoustic source localization. MMP consists of decomposing far-field acoustic data measured at an array of sensors to obtain the excitations of the propagating modes, then matching these with modeled replica excitations computed for a grid of possible source locations. However, modal decomposition can be ill-posed and unstable if the sensor array does not provide an adequate spatial sampling of the acoustic field (i.e., the problem is underdetermined). For such cases, standard decomposition methods yield minimum-norm solutions that are biased towards zero. Although these methods provide a mathematical solution (i.e., a stable solution that fits the data), they may not represent the most physically meaningful solution. The new approach of regularized matched-mode processing (RMMP) carries out an independent modal decomposition prior to comparison with the replica excitations for each grid point, using the replica itself as the a priori estimate in a regularized inversion. For grid points at or near the source location, this should provide a more physically meaningful decomposition; at other points, the procedure provides a stable inversion. In this paper, RMMP is compared to standard MMP and matched-field processing for a series of realistic synthetic test cases, including a variety of noise levels and sensor array configurations, as well as the effects of environmental mismatch.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N E Collison, S E Dosso. 2000. Regularized matched-mode processing for source localization.. https://doi.org/10.1121/1.429338

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sound attenuation of polymerizing actin reflects supramolecular structures: viscoelastic properties of actin gels modified by cytochalasin D, profilin and alpha-actinin.

Polymerization and depolymerization of cytoskeletal elements maintaining cytoplasmic stiffness are key factors in the control of cell crawling. Rheometry is a significant tool in determining the mechanical properties of the single elements in vitro. Viscoelasticity of gels formed by these polymers strongly depends on both the length and the associations of the filaments (e.g. entanglements, annealings and side-by-side associations). Ultrasound attenuation is related to viscosity, sound velocity and supramolecular structures in the sample. In combination with a small glass fibre (2 mm x 50 microm), serving as a viscosity sensor, an acoustic microscope was used to measure the elasticity and acoustic attenuation of actin solutions. Changes in acoustic attenuation of polymerizing actin by far exceed the values expected from calculations based on changes in viscosity and sound velocity. During the lag-phase of actin polymerization, attenuation slightly decreases, depending on actin concentration. After the half-maximum viscosity is accomplished and elasticity turns into steady state, attenuation distinctly rises. Changes in ultrasound attenuation depend on actin concentration, and they are modulated by the addition of alpha-actinin, cytochalasin D and profilin. Thus absorption and scattering of sound on the polymerization of actin is related to the packing density of the actin net, entanglements and the length of the actin filaments. Shortening of actin filaments by cytochalasin D was also confirmed by electron micrographs and falling-ball viscosimetry. In addition to viscosity and elasticity, the attenuation of sound proved to be a valuable parameter in characterizing actin polymerization and the supramolecular associations of F-actin.

Acoustics↗

A strategy for chemical sensing based on frequency tunable acoustic devices.

A new acoustic sensor geometry, the magnetic acoustic resonant sensor (MARS), is described. The device comprises a circular 0.5-mm-thick resonant plate fabricated from a wide variety of nonpiezoelectric materials and coated on the underside with a 2.5-microm-thick aluminum film. Harmonic radial shear waves over at least a 2 orders of magnitude frequency range can be induced in the resonant plate by enhanced magnetic direct generation using a noncontacting rf coil and NdFeB magnet. Mass loading with adherent aluminum films produced frequency changes of 106 Hz/nm (40.8 Hz/ng-mm(-2)), while contact with viscous fluids resulted in maximum changes of 15 446 Hz/cP. At an operating frequency of 50 MHz, the device detected viscosity changes as low as 0.0006 cP. The adsorption of proteins such as human IgG and the binding of a complementary antigen, goat anti-human IgG, on the upper nonmetallized surface of the device has been monitored with a detection limit of approximately 75 ng/mL. The binding of substrates and allosteric effectors to glycogen phosphorylase b has provided evidence that the device is very sensitive to viscoelastic changes in adsorbed proteins. The MARS device generates radial shear acoustic waves over a broad bandwidth that are unaffected by the conductivity of the solution. These results suggest that simple metal, glass, crystalline, or polycrystalline plates can be used as a new type of tunable acoustic immunosensor.

Acoustics↗

A reconsideration of sound calibration in the mouse.

Although it is traditional to perform sound calibrations in anesthetized animals by placing a probe-tube microphone near the tympanic membrane, these measurements are inaccurate at high stimulus frequencies where hearing must be quantified in the mouse. Hence, our motivation to develop another approach using the mouse ear canal as a coupler. Results of real-ear-canal calibrations indicate that an average calibration can be used to estimate sound pressure levels in the three mouse strains tested. Similar estimates were also obtained using a tubing coupler, whose volume was comparable to that of the ear canal, thereby offering a simpler alternative. In addition, real-head calibrations were also performed to provide a procedure that can be used in situations where the ear is not dissected, as in measurements of the auditory brainstem response. Calibrations for open, rather than closed, sound-delivery systems were also evaluated using a modified method of substitution.

Acoustics↗