Search PubMed⌕ Search

PubMed · 10870705

Three-dimensional sonoelastography: principles and practices.

Abstract

Sonoelastography is an ultrasound imaging technique where low amplitude, low-frequency shear waves (less than 0.1 mm displacement and less than 1 kHz frequency) are propagated through internal organs, while real-time Doppler techniques are used to image the resulting vibration pattern. When a discrete hard inhomogeneity, such as a tumour, is present within a region of soft tissue, a decrease in the vibration amplitude will occur at its location. This forms the basis for tumour detection using sonoelastography. For three-dimensional (3D) imaging the acquisition of sequential tomographic slices using this technique, combined with image segmentation, enables the reconstruction, quantification and visualization of tumour volumes. Sonoelastography and magnetic resonance images (MRI) of a tissue phantom containing a hard isoechoic inclusion are compared to evaluate the accuracy of this method. The tumour delineation from sonoelastography was found to have good agreement with the tumour from MRI except for a bleeding at one of its ends. Although sonoelastography is still in an experimental phase, the principles behind this imaging modality are explained and some practical aspects of acquiring sonoelastography images are described. Results from a 3D sonoelastography reconstruction of a tissue mimicking phantom and an ex vivo whole prostate specimen are presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L S Taylor, B C Porter, D J Rubens, K J Parker. 2000. Three-dimensional sonoelastography: principles and practices.. https://doi.org/10.1088/0031-9155%2F45%2F6%2F306

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The process of lubrication impairment and its involvement in temporomandibular joint disc displacement: a theoretical concept.

PURPOSE: This article re-evaluates the chain of events leading to temporomandibular joint (TMJ) disc displacement. The joint lubrication system and the process of its breakdown are clarified and an attempt is made to evaluate the possible effect of increased friction between the disc and fossa on the anterior displacement of the disc. MATERIALS AND METHODS: The study is based on the author's accumulated clinical data and results obtained from laboratory investigations regarding TMJ lubrication and its possible breakdown, coupled with pertinent information culled from the literature. RESULTS: Translation of the disc in the TMJ is enabled due to the presence of phospholipids and hyaluronic acid, which constitute an efficient lubrication system. This system may break down in the presence of uncontrolled free radicals. In the absence of lubricants, the articular surfaces are smooth, elastic in texture, and possess strong surface energy. Such opposing planes, especially in the presence of a thin fluid film (sub-boundary lubrication) tend to generate high friction while the disc is sliding against the fossa. Such friction is probably the prime mover in loosening the disc attachments to the condyle, with subsequent disc displacement. CONCLUSIONS: Increased friction of the contiguous parts may well be a major causative factor in displacement of the articular disc. This should be taken into account in considering the appropriate treatment approach. It also raises some doubts regarding the validity of using repositioning techniques.

Elasticity↗

The fractional free volume of the sorbed vapor in modeling the viscoelastic contribution to polymer-coated surface acoustic wave vapor sensor responses.

Surface acoustic wave (SAW) vapor sensors with polymeric sorbent layers can respond to vapors on the basis of mass loading and modulus decreases of the polymer film. The modulus changes are associated with volume changes that occur as vapor is sorbed by the film. A factor based on the fractional free volume of the vapor as a liquid has been incorporated into a model for the contribution of swelling-induced modulus changes to observed SAW vapor sensor responses. In this model, it is not the entire volume added to the film by the vapor that contributes to the modulus effect; it is the fractional free volume associated with the vapor molecules that causes the modulus to decrease in a manner that is equivalent to free volume changes from thermal expansion. The amplification of the SAW vapor sensor response due to modulus effects that are predicted by this model has been compared to amplification factors determined by comparing the responses of polymer-coated SAW vapor sensors with the responses of similarly coated thickness shear mode (TSM) vapor sensors, the latter being gravimetric. Results for six to eight vapors on each of two polymers, poly(isobutylene) and poly(epichlorohydrin), were examined. The model predicts amplification factors of the order of about 1.5-3, and vapor-dependent variations in the amplification factors are related to the specific volume of the vapor as a liquid. The fractional free volume factor provides a physically meaningful addition to the model and is consistent with conventional polymer physics treatments of the effects of temperature and plasticization on polymer modulus.

Elasticity↗

Viscoelastic finite-element analysis of a lumbar motion segment in combined compression and sagittal flexion. Effect of loading rate.

STUDY DESIGN: A study using a validated viscoelastic finite-element model of a L2-L3 motion segment to identify the load sharing among the passive elements at different loading rates. OBJECTIVE: To enhance understanding concerning the role of the loading rate (i.e., speed of lifting and lowering during manual material handling tasks) on the load sharing and safety margin of spinal structures. SUMMARY OF BACKGROUND DATA: Industrial epidemiologic studies have shown that jobs requiring a higher speed of trunk motion contribute to a higher risk of industrial low back disorders. Consideration of the dynamic loading characteristics, such as lifting at different speeds, requires modeling of the viscoelastic behavior of passive tissues. Detailed systematic analysis of loading rate effects has been lacking in the literature. METHODS: Complex flexion movement was simulated by applying compression and shear loads at the top of the upper vertebra while its sagittal flexion angle was prescribed without constraining any translations. The lower vertebra was fixed at the bottom. The load reached its maximum values of 2000 N compression and 200 N anterior shear while L2 was flexed to 10 degrees of flexion in the three different durations of 0.3, 1, and 3 seconds to represent fast, medium, and slow movements, respectively. The resisted bending moment, gross load-displacement response of the motion segment, forces in facet joints and ligaments, stresses and strains in anulus fibrosus, and intradiscal pressure were compared across different rates. RESULTS: The distribution of stress and strain was markedly affected by the loading rate. The higher loading rate increased the peak intradiscal pressure (12.4%), bending moment (20.7%), total ligament forces (11.4%), posterior longitudinal ligament stress (15.7%), and anulus fiber stress at the posterolateral innermost region (17.9%), despite the 15.4% reduction in their strain. CONCLUSIONS: Consideration of the time-dependent material properties of passive elements is essential to improving understanding of motion segment responses to dynamic loading conditions. Higher loading rate markedly reduces the safety margin of passive spinal elements. When the dynamic tolerance limits of tissues are available, the results provide bases for the guidelines of safe dynamic activities in clinics or industry.