Search PubMed⌕ Search

PubMed · 10869764

A simple and reliable method to simulate multileaf-plans.

Abstract

To combine conformity of the irradiation with time effectiveness during treatment, the use of multileaf collimators has become more and more common. However, the simulation of the leaf positions is rather difficult compared with metal blocks. We developed a new method, utilizing an acrylic template in which the contour produced by the leaves is machined in the form of a 1 mm groove by a computerized numerically controlled milling machine. This template is then inserted into a mount attached to the simulator. The main advantages are the errorfree, direct communication from the therapy planning system to the milling machine via a network, the possibility to transfer the contour to the skin, and the documentation on the simulation film. The use of templates is reliable and, e.g. the costs of the materials are lower than for block simulation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W W Baus, M Brauns, K Müller-Sievers, B Kober. 2000. A simple and reliable method to simulate multileaf-plans.. https://doi.org/10.1016/s0167-8140(00)00186-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The need for rotational margins in intensity-modulated radiotherapy and a new method for planning target volume design.

PURPOSE: The effect of rotational errors on the coverage of clinical target volumes (CTVs) is examined. A new planning target volume (PTV) construction that considers the individual paths traced by movements of the target boundary points is developed. METHODS AND MATERIALS: A standard uniform margin expansion was compared with a PTV constructed from the space swept out by a concave moving target. A new method formed the PTV by aggregating the separate convex hulls taken of the positions of the individual target boundary points in a sampling of CTV displacements. RESULTS: A 0.5-cm uniform margin adequate for translations was inadequate given CTV rotation about a fixed off-center axis. A PTV formed of the target's swept-out area was 22% smaller than needed for coverage by a uniform margin, but computationally is not readily extended to translations combined with rotations about a shifting axis. Forming instead the union of convex hulls of the boundary points in a sampling of CTV displacements represented these movements in the PTV design and retained the target's concave shape. CONCLUSIONS: Planning target volumes should accommodate target rotation. The union of convex hulls of the boundary point positions in a sampling of displacements can effectively represent multiple sources of deviations while preserving target concavities.

Radiotherapy Planning, Computer-Assisted↗

Assessment of the acceptability of the Elekta multileaf collimator (MLC) within the Corvus planning system for static and dynamic delivery of intensity modulated beams (IMBs).

The sliding window technique used for static and dynamic segmentation of intensity modulated beams is evaluated. Dynamic delivery is preferred since the resulting distributions correspond better with the calculated distributions, the treatment beam is used more efficiently and the delivery is less sensitive to small variations in the accuracy of the multileaf collimator (MLC).

Radiotherapy Planning, Computer-Assisted↗

Dosimetric characteristics of a double-focused miniature multileaf collimator.

The dosimetric characteristics of a double-focused miniature multileaf collimator (mMLC) attached to a Philips SL75/5 linear accelerator (linac) have been investigated. Output factors, percentage depth-dose, penumbra, leaf transmission, and leakage between the leaves were measured for the 6 MV x-ray beam on this accelerator. Because leakage both through and between the leaves is minimal, the linac jaws can be kept fixed while the mMLC leaf configuration is modified for different aperture shapes. This allows for accurate output prediction using the equivalent square formalism. Percent depth-dose measured for fields defined by the mMLC show little deviation from the percent depth-dose measured for fields defined by the machine jaws or Lipowitz metal blocks. Because the mMLC matches beam divergence in both directions, allows minimal beam transmission, and has a large source-to-collimator distance, the penumbra is sharper for fields defined by the mMLC than for fields defined by the linac jaws or Lipowitz metal blocks. Based on these data, dose calculations for mMLC-defined fields can be applied with no change in procedures from those used for fields defined using conventional methods.

Radiotherapy Planning, Computer-Assisted↗