Search PubMed⌕ Search

PubMed · 10845796

Dynamic microwave-assisted extraction.

Abstract

An apparatus for extraction of solid matrices has been constructed which utilizes a microwave technique for heating in a dynamic mode. During the extraction, fresh solvent is continuously pumped through the extraction cell, which is maintained at a slight overpressure in order to keep the solvent in a liquid state. The extraction efficiency, which can be easily monitored, has been investigated in a factorial design and validated for polycyclic aromatic hydrocarbons in a reference sediment sample (EC-1). Important parameters were found to be temperature and duration of extraction. Flow-rate had no significant first-order effect on the recovery, but interaction effects with flow-rate were found to be significant. The dynamic microwave-assisted extraction apparatus was demonstrated to yield recoveries equivalent to Soxhlet extraction, but in a much shorter time. Each extraction of EC-1 typically takes 40 min.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Ericsson, A Colmsjö. 2000-04-28. Dynamic microwave-assisted extraction.. https://doi.org/10.1016/s0021-9673(00)00246-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simple determination of mycophenolic acid in human serum by column-switching high-performance liquid chromatography.

A column-switching high-performance liquid chromatographic analysis was established to monitor the serum concentration of mycophenolic acid, the active metabolite from mycophenolate mofetil administered for the prophylaxis of acute organ rejection in renal transplantation. The system consisted of two pumps for solvent delivery, a column-switching valve, a precolumn, and a reversed-phase analytical column. The present method enabled us to determine MPA by injecting serum samples directly into HPLC without any pretreatment. The mobile phases with different amounts of organic solvent were delivered to the precolumn and analytical column by separate lines, and samples were applied to the precolumn. The column switching valves were switched automatically following the processes for the elimination of protein and the drug analysis. The peak heights of MPA were linearly related to the concentrations (r=0.999) in the range of 0.1-20 micro g/ml, and the limit of quantification was 0.1 micro g/ml (S/N ratio=3). This method was accurate and reproducible on the basis of the results of recovery (94.0-98.0%) and small coefficient of variations of intra and inter-assay (less than 8.3%).

Chromatography, High Pressure Liquid↗

Determination of a peptide-doxorubicin, prostate-specific antigen activated prodrug, and its active metabolites in human plasma using high-performance liquid chromatography with fluorescence detection. Stabilization of the peptide prodrug with EDTA.

A method for the determination of I, a peptide-doxorubicin conjugate that was evaluated for the treatment of prostate cancer, and two of its active metabolites, doxorubicin and leucine-doxorubicin is described. Blood samples were chilled immediately after being drawn in order to prevent ex vivo entry of the metabolites into red blood cells. EDTA (10 mg/ml final concentration) was used to prevent plasma-mediated degradation of the peptide portion of the prodrug. After the addition of internal standard, plasma was prepared for analysis using a C-8 solid-phase extraction column. In order to overcome secondary ionic interactions with the silica-based extraction column, the analytes were eluted with ammonium hydroxide in methanol. The extracts were evaporated to dryness, reconstituted, and assayed by step change, gradient, reverse phase HPLC with fluorescence detection. Two interfering metabolites found in post dose plasma were chromatographically separated by an adjustment of the mobile phase pH. The within-day reproducibility of the doxorubicin and leucine-doxorubicin chromatographic retention times was improved by a brief washing of the analytical column with 90% acetonitrile after each injection. The range of the standard curve was 12.5-1250 ng/ml for doxorubicin and 25-2500 ng/ml for I and leucine-doxorubicin.

Chromatography, High Pressure Liquid↗

Simple and rapid high-performance liquid chromatographic method for nelfinavir, M8 nelfinavir metabolite, ritonavir and saquinavir assay in plasma.

A simple reversed-phase liquid chromatographic method has been developed to determine protease inhibitors concentrations in plasma. Plasma samples (250 micro l) containing protease inhibitors were prepared by a simple deproteinization (recovery: 92, 91, 91 and 90.5% for ritonavir, saquinavir, nelfinavir and M8 nelfinavir metabolite, respectively). Chromatography was accomplished using a Hypersil octadecylsilyl column (100 x 4.6 mm I.D.) and a mobile phase composed of acetonitrile, tetrahydrofuran and dihydrogenophosphate buffer (pH 4) (32:10:58, v/v). Ultraviolet detection at 210 nm was used. The limit of detection was 200 ng/ml for ritonavir, saquinavir, nelfinavir and M8 nelfinavir metabolite. Calibration curves were linear up to 20000 ng/ml, with correlation coefficients better than 0.997 for all compounds. Intra- and inter-day coefficients of variation of the assay were <or=6% for all compounds. This method was used to analyse protease inhibitors plasma concentrations after oral administration within the framework of therapeutic drug monitoring and pharmacokinetic studies in AIDS patients.

Chromatography, High Pressure Liquid↗