Search PubMed⌕ Search

PubMed · 10840465

Changes in urine macromolecular composition during processing.

Abstract

PURPOSE: To determine the urinary crystallization inhibitory activity, urine is generally centrifuged and/or filtered. These preparative procedures may result in a total or partial removal of many macromolecular constituents implicated in crystallization. The main purpose of this study was to investigate the changes in urinary macromolecular composition following centrifugation and filtration. MATERIALS AND METHODS: Twenty-four hour urine samples were collected from human volunteers. Each was divided into 4 aliquots; one was filtered, the other was centrifuged, another was centrifuged and filtered. The control sample was neither filtered nor centrifuged. Total protein and lipid contents of each sample were determined. Proteins were analyzed using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Western blot analysis was performed using antibodies against osteopontin (OPN), prothrombin (PT) related proteins, inter-alpha-inhibitor (IalphaI) related proteins, Tamm-Horsfall protein (THP), and albumin (ALB). The effect of processing on incorporation of urinary proteins in crystal matrices was also examined. Calcium oxalate crystals were produced in processed and unprocessed urine samples by the addition of sodium oxalate. Crystals were harvested, de-mineralized and their proteins analyzed by SDS-PAGE and Western blotting. RESULTS: Processing reduced the amounts of both proteins and lipids in the urine. Previously we identified phospholipids in the matrix of calcium oxalate crystals as well as the filtrate and retentate removed during filtration and centrifugation. Phospholipids have a high affinity for calcium-containing crystals. In the case of proteins, those with high molecular weights appeared to be clearly affected by filtration and centrifugation. Processing also appeared to influence the incorporation of proteins in the crystals. The matrix of crystals produced in processed urine contained less THP than those made in unprocessed urine, apparently a result of the loss of this higher molecular weight protein during processing. Incorporation of PT-related proteins, particularly fragment 1, was increased. CONCLUSIONS: We propose that selective inclusion of macromolecules is a result of an increase in available binding sites on crystal surfaces because of the removal of certain calcium binding substances such as phospholipids and proteins. Removal of larger macromolecules from the milieu may also provide a better access to the crystal surfaces.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Maslamani, P A Glenton, S R Khan. 2000. Changes in urine macromolecular composition during processing.. https://pubmed.ncbi.nlm.nih.gov/10840465/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Centrifugal concentrator for the substitution of nitrogen blow-down micro-concentration in dioxin/polychlorinated biphenyl sample preparation.

A centrifugal concentrator was applied for the substitution of nitrogen blow-down micro-concentration in dioxin/PCB sample preparation. Automation was achieved through this apparatus and resulted in significant improvements in sample preparation productivity, along with excellent reproducibility and recovery rate of dioxin/PCB. Mean recoveries of dioxin congeners were 90-106%, respectively.

Centrifugation↗

Inlet port positioning for a miniaturized centrifugal blood pump.

We are developing the Baylor-Kyocera KP implantable centrifugal blood pump for small sized adult and pediatric patients. This pump eccentrically positions the inlet port, which eliminates flow stagnation around the top pivot bearing. The inlet port design is important because it may vary the inlet orifice pressure on the top housing and change hydraulic performance and hemolytic characteristics. The pressure distribution inside the KP pump was assessed by a computational fluid dynamic (CFD) analysis with 2.7 x 10(5) elements and 3.16 x 10(5) nodes. Hydraulic performance and hemolysis were evaluated with 3 different pump housings, which had 3.8, 4.5, and 6.1 mm offset inlet ports from the center in a mock circuit. The CFD analysis revealed that the pressure gradually increased from the center toward the peripheral. The pressure difference between the 3.8 to 6.1 mm offsets was less than 600 Pa. The hydraulic performance did not drastically change at 3.8, 4.5, and 6.1 mm offset from the center. However, the hemolysis increased with the increase of the port offset from 0.0080+/- 0.0048 to 0.054 +/- 0.028 g/100 L. The inlet port positioning is important to attain less blood trauma in this small Gyro centrifugal blood pump. The preferable position of the inlet port is less than 4.5 mm offset from the center.

Centrifugation↗

Impeller inner diameter in a miniaturized centrifugal blood pump.

To design a miniaturized centrifugal blood pump, the impeller internal diameter (ID), which is a circle diameter on the inner edge of the vane, is considered one of the important aspects. Hydraulic performance, hemolysis, and thrombogenicity were evaluated with different impeller IDs. Two impellers were fabricated with an outer diameter of 35 mm, of which 1 had an 8 mm ID impeller and the other had a 12 mm ID. These impellers were combined with 2 different housings in which the inlet port was eccentrically positioned 3.8 and 4.5 mm offset from the center. The hydraulic performance and hemolysis were evaluated in a mock circuit, and thrombogenicity was evaluated in a 2 day ex vivo study with each impeller housing combination. Both impellers required 3,000 rpm in the 3.8 mm offset inlet to attain 5 L/min against 100 mm Hg (left ventricular assist device condition). The 8 mm ID impeller required 3,200 rpm, and the 12 mm ID impeller required 3,100 rpm in the 4.5 mm offset housing. The normalized index of hemolysis was 0.0080 +/- 0.0048 g/100 L in the 8 mm ID impeller with the 3.8 mm offset and 0.022 +/- 0.018 g/100 L with 4.5 mm offset. The 12 mm ID impeller had 0.068 +/- 0.028 g/100 L with the 3.8 mm offset and 0.010 +/- 0.002 g/100 L with the 4.5 mm offset. After the 2 day ex vivo study, no blood clot was formed around the top bearing in all the pump heads. The 8 mm ID impeller with 3.8 mm offset inlet and the 12 mm ID impeller with the 4.5 mm offset had less hemolysis compared to the other pump heads that were subjected to 14 day ex vivo and 10 day in vivo studies. The 8 mm ID impeller with the 3.8 mm offset inlet had a blood clot around the top bearing after the 14 day ex vivo study. No thrombus was found around the top bearing of the 12 mm ID impeller with the 4.5 mm offset in the 10 day in vivo study. These results suggest that the ID does not greatly change the hydraulic performance of a small centrifugal blood pump. The proper combination of the impeller ID and inlet port offset obtains less hemolysis. The larger impeller ID is considered to have less thrombogenicity around the top bearing.

Centrifugation↗