Search PubMed⌕ Search

PubMed · 10818884

Extraanatomic bypass surgery.

Abstract

The term "extraanatomic bypass" applies to grafts that pass through a different anatomic pathway than do the natural blood vessels they replace. These grafts are devised to circumvent complex problems when conventional vascular procedures are not possible or are too hazardous to perform. There are various indications, advantages, and disadvantages to each of these grafts. Extraanatomic bypass grafts are an accepted technique with known patency rates. Quality nursing care plays a significant role in successful patient outcome.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V A Fahey, A Milzarek. 1999. Extraanatomic bypass surgery.. https://doi.org/10.1016/s1062-0303(99)90012-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Impact of three-dimensional characteristics of the left main coronary artery bifurcation on outcome of crush stenting.

BACKGROUND: Crush stenting with drug-eluting stents is used to treat left main coronary artery (LMCA) bifurcations. However, the rate of restenosis at the left circumflex (LCX) artery ostium is high. The impact of the three-dimensional (3D) structure of LMCA bifurcation on the outcome of crush stenting with respect to restenosis has not been described. OBJECTIVES: This study examined the stent expansion, deformity, overlapping, and apposition after crush stenting of LMCA bifurcations. METHODS: Bare metal stents were crushed at LMCA bifurcations in a 3D model that reproduced actual angles, such that the stent deployed from the LMCA to the left anterior descending (LAD) artery crushed the stent deployed from the LMCA to the LCX, followed by kissing balloon inflation. The stents were inspected under fluoroscopy and endoscopy. The effect of the bifurcation angle on stent expansion was also examined. RESULTS: In the 3D model, one stent overlapped the other in the distal LMCA, in contrast to the nearly parallel position of the stents observed in a separate two-dimensional model. When the LAD stent overlapped the LCX stent, the latter was crushed on the myocardial side of the vessel, and an unstented segment was observed on the nonmyocardial side, at the LCX ostium. When the overlap was reversed, the LCX stent was crushed on the nonmyocardial side and an unstented segment was observed on the myocardial side. A narrow LMCA-LCX angle was associated with less expansion of the LCX stent at the ostium than more distally, and with a higher likelihood of incomplete stent apposition. CONCLUSIONS: Overlap of the LAD stent over, as opposed to under, the LCX stent was associated with close apposition of the stent to the vessel on the myocardial side, at the ostium of the LCX artery, where atherosclerotic plaques are likely to be present. The spatial plaque burden and bifurcation angle should be closely examined before crush stenting, and segments should not be left unstented over large plaques.

Blood Vessel Prosthesis Implantation↗

Endovascular repair of an iliac artery aneurysm in a patient with Ehlers-Danlos syndrome type IV.

Ehlers-Danlos type IV (EDS-IV) is an inherited condition most notable for its associated vascular complications. Patients are prone to aneurysm formation, arterial dissection, and spontaneous vessel rupture. Intervention for the vascular pathology of EDS-IV carries high morbidity and mortality. We describe a case of a 57-year-old man with EDS-IV and an expanding iliac aneurysm who underwent successful endovascular repair with a stent-graft. Endovascular aneurysm repair is feasible and should be considered for patients with EDS-IV.

Blood Vessel Prosthesis Implantation↗