PubMed · 10794776

Modular robotic workcell for coagulation analysis.

Abstract

BACKGROUND: Total laboratory automation (TLA) has been shown to increase laboratory efficiency and quality. However, modular automation is smaller, requires less initial capital, and requires less planning than TLA. We engineered and performed clinical trials on a modular robotic preanalytical workcell for coagulation analysis. METHODS: Timing studies were used to quantify the efficiency of the manual processes and to identify areas in the processing of coagulation specimens where bottlenecks and long waiting periods were encountered. We then designed our modular robotic system to eliminate these bottlenecks. Our robotic modular workcell was engineered to allow a choice of specimen introduction manually, by conveyor, or by mobile robot. Additional timing studies were performed during clinical trials of the robotic system. RESULTS: Prior to automation, the time required for preanalytical processing time was 18-107 min; after automation, it was 45-50 min. Additional improvements in workcell efficiency could be realized when high quality, prelabeled specimens were introduced into the system. CONCLUSION: Compared with manual methods, modular automation provides more predictable variation in specimen processing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Graves, B Holman, R A Felder. 2000. Modular robotic workcell for coagulation analysis.. https://pubmed.ncbi.nlm.nih.gov/10794776/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development and evaluation of an isotope dilution LC/MS method for the determination of total homocysteine in human plasma.

Elevated plasma homocysteine has been identified as a strong and independent risk factor for cardiovascular diseases, and recently, it has been associated with the development of dementia in older adults. Selected ion-monitoring isotope-dilution LC/MS (electrospray) has been developed and evaluated as a reference method for the accurate determination of total homocysteine in human plasma. Homocysteine is quantitatively isolated from plasma via the use of anion-exchange resins and then detected and quantified in stabilized plasma extracts with selected ion-monitoring LC/MS. This method is shown to be highly comparable to LC/MS/MS determinations in terms of its analytical accuracy and precision, yet this alternative measurement approach does not necessitate the enhanced instrumentation or added expense required of tandem MS/MS determinations. LC/MS detection of homocysteine was linear (standard error of the estimate for the regression line was 0.0323) over 3 orders of magnitude, and the calculated limits of detection and quantification were 0.06 micromol/L (0.12 ng on column) and 0.6 micromol/L (1.2 ng on column), respectively. Independent calibration curves showed excellent linearity (r2 > or = 0.996) between 0 and 25 micromol/L homocysteine over a 3-day period. The accuracy and precision of total homocysteine measurements for patient samples and quality control pools using LC/MS were compared to total homocysteine measurements using LC/MS/MS, GC/MS, FPIA, and LC-FD. LC/MS performed well in relation to the other homocysteine methods in terms of its capability to accurately quantify plasma homocysteine over the normal range (5-15 micromol/L).

Blood Chemical Analysis↗

New enzymatic assay for serum urea nitrogen using urea amidolyase.

We established an enzymatic assay for measurement of serum urea nitrogen using urea amidolyase (EC 3.5.1.45) from yeast species. The method is based on hydrolysis of urea by the enzyme. In this assay, we eliminated endogenous ammonium ion by use of glutamate dehydrogenase (EC 1.4.1.4). Then in the presence of urea amido-lyase, ATP, bicarbonate, magnesium, and potassium ions, ammonium ion was produced proportionally to urea concentration in serum. The concentra-tion of ammonium ion formed was determined by adding GLDH to produce NADP(+) in the presence of 2-oxoglutarate and NADPH. We then monitored the change of absorbance at 340 nm. The inhibitory effect of calcium ion on this assay was eliminated by adding glyco-letherdiamine-N, N, N', N'-tetraacetic acid to the reaction system. The with-in-assay coefficient of variations (CVs) of the present method were 1.80-3.76% (n = 10) at 2.8-19.0 mmol/L, respectively. The day-to-day CVs were 2.23-4.59%. Analytical recovery was 92-115%. The presence of ascorbic acid, bilirubin, hemoglobin, lipemic material, ammo-nium ion, or calcium ion did not affect this assay system. The correlation be-tween values obtained with the present method (y) and those by another enzy-matic method (x) was 0.997 (y = 1.02x - 0.10 mmol/L, Sy/x = 0.841, n = 100), with a mean difference of -0.18 +/- 0.86 mmol/L [(values by reference method - that of present method) +/- SD] using the Bland-Altman technique. J. Clin. Lab. Anal. 17:52-56, 2003.

Blood Chemical Analysis↗

Optimization of the purification method for dioxin analysis in human serum and temporal changes in background dioxin levels in the general population.

To perform high quality and high throughput measurements, complicated purification procedure by two rounds of open column chromatography was simplified by appraising the components and adding a sufficient amount of adsorbents to the column. The procedure consists of two open column techniques using a multi-layer silica gel column and an active carbon dispersed silica gel column. This purification procedure is used in "Standard manual for dioxin analysis in human blood" published in 2000 (Ministry of Health and Welfare, Japan, 2000). Consequently, a purification procedure using only 1 g of 10% AgNO(3)/silica gel can remove the matrix of blood serum as effectively as a multi-layer silica gel column. In addition, 0.1 g of carbon silica gel, equivalent to 1/10 the weight used currently in analyses, separates and recovers the dioxins in purified extract of blood serum. Furthermore, changes in the background level in the general population were clarified by monitoring the dioxin concentrations in human blood. The dioxin concentrations and ratios in blood in the general population remained at a tolerable level for three months. Therefore, the blood serum was available for the detection of a remarkable elevation in dioxins level considered to be indicative of contamination due to high-density exposure.

Blood Chemical Analysis↗