A bench-top method for evaluating modular total hip component combinations.

Abstract

A modular total hip prosthesis allows the surgeon to vary head size, neck length, and acetabular coverage. Different combinations, however, may increase the risk of impingement of the prosthesis neck on the acetabular liner, leading to dislocation. We developed a bench-top model to test different modular component combinations to determine how far the femoral component could travel within the acetabular liner before impingement led to dislocation. We tested two hip systems, each from a different manufacturer. Certain components increased the risk of impingement and dislocation: skirted necks, smaller heads, and lipped liners. While the contribution of each component was small, the risk was additive, so that the combination of a small head with a skirted neck in a lipped liner actually reduced the available range of motion by 18 degrees, from 146 degrees to 128 degrees, in the first system, and by 13 degrees, from 156 degrees to 143 degrees in the other. This method could be adapted to test a wide range of component configurations, from a number of manufacturers. These findings may be useful in avoiding potentially unstable configurations when given a choice of modular components.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R L Uhl, S C Williamson, R Williams, W Andrews, J Hutchison. 2000. A bench-top method for evaluating modular total hip component combinations.. https://pubmed.ncbi.nlm.nih.gov/10784019/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement.

In Europe and the USA combined, over half a million people had a hip joint replaced in 2005, contributing to the increasing number of radiotherapy patients with metallic hip prostheses. The treatment plan for external beam radiation therapy is based on the delineation of the anatomy in the planning CT scan. When implanted objects of high atomic number (Z) material are present, however, severe image artefacts are generated in conventional CT, strongly hindering the ability to delineate some organs. This is particularly the case for the planning of prostate patients with hip prostheses. This short communication presents the use of a new imaging modality, megavoltage cone-beam CT, to complement the regular CT for target definition of prostate cancer treatment of patients with hip replacements.

Hip Prosthesis↗

Stem damage during implantation of modular hip prostheses.

Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to assess if stem holders of modular prostheses can induce any stem damage, and if so, to identify the features that provide minimal damage. Two different stem holder connector designs were investigated. The surface of the stem cavity was inspected to identify the damage caused by the use of the two connectors after a simulated surgical handling. Both connectors induced some damage, with significantly more damage being caused by a supposedly improved design. Scars due to contact with the stem holder were observed on the stem cavity surface. This may be sufficient to trigger increased fretting damage during service life, causing the production of fretting debris.

Hip Prosthesis↗