Polydimethylsiloxane/polyether-mixed macrodiol-based polyurethane elastomers: biostability.

Abstract

A series of four thermoplastic polyurethane elastomers were synthesized with varying proportions of poly(hexamethylene oxide) (PHMO) and poly(dimethylsiloxane) (PDMS) macrodiols. The macrodiol ratios (by weight) employed were (% PDMS:% PHMO) 100:0, 80:20, 50:50 and 20:80. The weight fraction of macrodiol in each polymer was fixed at 60%. The mixed macrodiols were reacted with 4,4'-methylenediphenyl diisocyanate (MDI) and 1,4-butanediol (BDO) chain extender. The biostability of these polymers was assessed by strained subcutaneous implantation in sheep for three months followed by microscopic examination. Pellethane 2363-80A and 2363-55D were employed as control materials. The mechanical properties of the polymers were tested and discussed along with the biostability results. The results showed that soft, flexible PDMS-based polyurethanes with very promising biostability can be successfully produced using the mixed macrodiol approach. The formulation with 80% PDMS macrodiol produced the best result in terms of a combination of flexibility, strength and biostability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D J Martin, L A Warren, P A Gunatillake, S J McCarthy, G F Meijs, K Schindhelm. 2000. Polydimethylsiloxane/polyether-mixed macrodiol-based polyurethane elastomers: biostability.. https://doi.org/10.1016/s0142-9612(99)00271-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator.

The most commonly used wear test device for prosthetic hip joints is the so-called biaxial rocking motion (BRM) design. The design has been criticized for its excessive sliding distance per cycle. The design was modified so that the extent of motion was reduced from 46 to 23 degrees, and comparative tests were run with the use of 1-kN static load. The present authors have earlier used 1-kN static load with good results. To further confirm this finding, additional, comparative tests were run with double-peak dynamic load and 46 degrees extent of motion. All three tests (46 degrees /static, 23 degrees /static and 46 degrees /dynamic), were done with conventional ultra-high-molecular-weight polyethylene acetabular cups against polished CoCr femoral heads in diluted calf serum lubricant. In all tests, the principal cup wear mechanism was adhesive, manifested as burnishing. With respect to wear particles, those produced in the 46 degrees /dynamic test showed the lowest resemblance to particles isolated from periprosthetic tissues. The 46 degrees /dynamic test produced a mean wear rate 43% higher than 46 degrees /static, whereas the 46 degrees /static and 23 degrees /static tests produced almost identical values. The results indicated that the 46 degrees extent of motion and dynamic load may not always be the optimal combination in BRM tests.

Biocompatible Materials↗

Composition and in vitro biocompatibility of corroding tungsten coils.

The purpose of the article is to evaluate composition and biocompatibility of corroding mechanically detachable spirals (MDS, Balt Extrusion, Montmorency, France). Analysis of the material composition of corroding MDS coils was assessed by inductively coupled plasma atomic emission spectroscopy, inductively coupled plasma mass spectroscopy, and wavelength-dispersive x-ray spectrometry. Toxicity assays were performed with human venous endothelial cells, venous smooth muscle cells and fibroblasts. The analyses of the MDS coils demonstrated a tungsten content of the dissolving MDS spirals of > 99.9 mas%. In vitro, human endothelial, vascular smooth muscle cells and fibroblasts were not adversely affected by markedly elevated tungsten concentrations (60,500 microg/l) after 12 days in the culture medium. The examined cells showed an extensive vital growth on the coil surface. Corrosion of tungsten coils leads to markedly elevated tungsten levels in the culture medium. However, growth and vitality of endothelial cells, fibroblasts, and vascular smooth muscle cells are not adversely affected by elevated tungsten concentrations.

Biocompatible Materials↗

Cell interaction studies of PLA-MePEG nanoparticles.

Poly(D,L-lactic acid)-methoxypoly(ethylene glycol) (PLA-MePEG) copolymers were synthesized by ring-opening polymerization of D,L-lactide in the presence of MePEG of different molecular weights and stannous octoate as the catalyst. The chemical composition of the diblock-copolymer PLA-MePEG was confirmed by 1H-NMR and the molecular weight and distribution were assessed by gel permeation chromatography. Nanoparticles containing Nile red as a fluorescent dye were prepared using poly(D,L-lactic acid) (PLA), blends of PLA and PLA-MePEG or PLA-MePEG alone. Incubation of nanoparticles with human blood monocytes was performed in serum or in PBS and the cell-associated fluorescence was analyzed by flow cytometry. In serum, a protective effect was obtained and the interaction of particles with mononuclear leukocytes decreased to 40%.

Biocompatible Materials↗