Search PubMed⌕ Search

PubMed · 10757186

Focal shift, optical transfer function, and phase-space representations.

Abstract

The focal shift for a lens of finite value of Fresnel number can be defined in terms of the second moment of the intensity distribution in transverse planes. The connection with the optical transfer function is described. The specification of the focused amplitude in terms of the fractional Fourier transform is discussed, and the connections among the fractional Fourier transform, the Wigner distribution, and the ambiguity function are described, leading to a model for effects of Fresnel number in terms of a rotation in phase space. The uncertainty principle is discussed, including the significance of the beam propagation factor M2 and the width of optical fiber beam modes. Calculation of the moments in terms of the modulus and the phase of the illuminating wave is presented, and the use of the Kaiser-Teager energy operator is also described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C J Sheppard, K G Larkin. 2000. Focal shift, optical transfer function, and phase-space representations.. https://doi.org/10.1364/josaa.17.000772

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Raman study of the interaction between polyamines and a GC oligonucleotide.

The interaction between the oligonucleotide d[G(CG)(7)]. d[C(GC)(7)] and the three biogenic polyamines putrescine, spermidine, and spermine under physiological conditions has been studied by Raman spectroscopy. The results indicate the formation of highly ordered aggregated structures in solution, largely stabilized by electrostatic attractions, which have been described as cholesteric phases. Aggregation seems to be preceded by a partial B --> Z conformational transition for spermidine and spermine, which would allow for a deeper oligonucleotide-polyamine interaction. Interaction with the nucleic bases has also been evidenced for aggregates. At low polyamine concentrations the preferential binding sites are similar to those proposed for their interactions with ct-DNA. With increasing the polyamine concentration, the oligonucleotide-polyamine interactions involve both minor and major grooves, which is consistent with the formation of cholesteric phases.

Fourier Analysis↗

Chemical transferability of single- and multiple-scattering EXAFS Debye-Waller factors.

Single- and multiple-scattering EXAFS Debye-Waller factors are amplitude reduction parameters that appear in the EXAFS chi(k) equation accounting for the structural and thermal disorder of a given sample. These parameters must be known accurately in order to obtain quantitative agreement between theory and experiment. Since experimental data can only support a limited number of fitted parameters these factors must be known from another source. Although various approaches have been considered in the past with a variety of results, the self-consistent ab initio Density functional theory stands for the most accurate and reliable method regardless of molecular symmetry or other specific sample requirements. Since DFT scales as N3 where N is the number of atomic basis set, an ab initio calculation on a large structure is not feasible due to enormous CPU demand and in many cases due to hard energy/geometry convergence. In this paper we present two ways of overcoming this problem. Both they use the idea that by reducing the structure, the DWFs are still chemically transferable. In order to test this we use the Zn tetraimidazole. This molecule represents typical metalorganic ring samples that can be seen in active sites of metaloproteins. Results are compared to experimental EXAFS spectra.

Fourier Analysis↗

Specific coil design for SENSE: a six-element cardiac array.

In sensitivity encoding (SENSE), the effects of inhomogeneous spatial sensitivity of surface coils are utilized for signal localization in addition to common Fourier encoding using magnetic field gradients. Unlike standard Fourier MRI, SENSE images exhibit an inhomogeneous noise distribution, which crucially depends on the geometrical sensitivity relations of the coils used. Thus, for optimum signal-to-noise-ratio (SNR) and noise homogeneity, specialized coil configurations are called for. In this article we study the implications of SENSE imaging for coil layout by means of simulations and imaging experiments in a phantom and in vivo. New, specific design principles are identified. For SENSE imaging, the elements of a coil array should be smaller than for common phased-array imaging. Furthermore, adjacent coil elements should not overlap. Based on the findings of initial investigations, a configuration of six coils was designed and built specifically for cardiac applications. The in vivo evaluation of this array showed a considerable SNR increase in SENSE images, as compared with a conventional array. Magn Reson Med 45:495-504, 2001.

Fourier Analysis↗