PubMed · 10703103

Spinous process strength.

Abstract

STUDY DESIGN: Mechanical testing of cadaveric lumbar spines and dual energy radiograph absorptiometry scanning were performed. OBJECTIVES: To devise a technique to measure the strength of lumbar spinous processes and to determine the bone mineral density of the vertebrae used. SUMMARY OF BACKGROUND DATA: The spinous process has been identified as the weakest part of the anatomy to which a flexible fixation device can be attached. It was unknown if the spinous processes could withstand the forces applied by the device. METHODS: A hook was fitted to the spinous process of 32 lumbar vertebrae. A custom-built rig was designed to secure a vertebra to a materials testing machine. A loop of cord was passed over a bar mounted on the crosshead of the machine and around the two bollards of the hook. As the crosshead was raised, a tension was applied to the cord. Each vertebra was tested to failure. The bone mineral density of each vertebra was then measured using dual energy radiograph absorptiometry. RESULTS: Failure of the specimens occurred by failure of the spinous process, pedicles, or vertebral body. The logarithm (base 10) of the load (N) at which failure occurred was 2.53 +/- 0.3, which corresponded to a mean failure load of 339 N. The bone mineral density of each vertebral body varied between 0.263 and 0.997 g/cm2. A significant linear correlation was found between bone strength and bone mineral density (P < 0.0001). CONCLUSIONS: Specimens with a bone mineral density in the range of 0.263-0.997 g/cm2 failed at a mean load of 339 N when the load was applied through the spinous process hook of a flexible fixation device.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D E Shepherd, J C Leahy, K J Mathias, S J Wilkinson, D W Hukins. 2000-02-01. Spinous process strength.. https://doi.org/10.1097/00007632-200002010-00010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗