Search PubMed⌕ Search

PubMed · 10680699

Field mapping without reference scan using asymmetric echo-planar techniques.

Abstract

Improvements in Bo mapping and shimming were achieved by measuring the static field information in multiple subsequent echoes generated by an asymmetric echo-planar readout gradient train. With careful compensation, eddy current effects were shown to affect the adjustment of the shim coils minimally. In addition to reducing the time required for field mapping by two-fold, the sensitivity was simultaneously optimized irrespective of the prevalent T2* present, thereby minimizing the error of the static field measurement to below 0.1 Hz. With adiabatic low flip-angle excitation, the time required for field mapping was below 1 second.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Gruetter, I Tkác. 2000. Field mapping without reference scan using asymmetric echo-planar techniques.. https://doi.org/10.1002/(sici)1522-2594(200002)43%3A2%3C319%3A%3Aaid-mrm22%3E3.0.co%3B2-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Symmetric echo acquisition for absolute-value display in solid-state NMR imaging.

A method of solid-state NMR imaging that permits echo Fourier transformation (FT) has been devised using a magic echo train. The echo FT imaging can be implemented simply by modifying the gradient pulse sequence in the previous magic echo imaging (TREV-16TS) so that the one-dimensional k-space trajectory follows the sampling points which are symmetric about the k origin. The implemented ability of echo FT improves the performance of the magic echo imaging: the sensitivity gained by radical2, the phase correction is made unnecessary, and the digital resolution is doubled. One- and two-dimensional imaging experiments have been conducted on some solid samples, confirming the improved performance and revealing a TREV-16TS adjustment parameter that is critical for the successful echo FT imaging.

Echo-Planar Imaging↗

In vivo 31P echo-planar spectroscopic imaging of human calf muscle.

Localized phosphorus-31 NMR spectra of human calf muscle in vivo were obtained by means of echo-planar spectroscopic imaging (EPSI) with a 1.5-T whole-body scanner. The technique permits the measurement of two-dimensional 31P SI data at a minimum acquisition time of 2.4 s (8x8 voxels, TR=300 ms). With 9.4 min measurement time (TR=1100 ms, 64 averages) and 25x25x40 mm spatial resolution in vivo the 31P NMR signal-to-noise ratio (S/N) of the phosphocreatine (PCr) resonance was about 45; the multiplets of nucleoside 5'-triphosphates were resolved. Spectral quality permits quantitative assessment of the PCr signal in a measurement time that is shorter by a factor of 2 or more than the minimum measurement time feasible with chemical-shift imaging. In a functional EPSI study with a time resolution of 20.5 s on the calf muscle of volunteers, spectra showed a 40% decrease of the PCr signal intensity (at rest: S/N congruent with12) upon exertion of the muscle.

Echo-Planar Imaging↗

Fetal and placental volumetric and functional analysis using echo-planar imaging.

Recent and past work using echo-planar imaging (EPI) in pregnancy has allowed important anatomic and physiological information to be obtained, giving advantages over conventional radiological methods such as ultrasound. EPI is a quick, convenient method of measuring organ volumes. The volumetric estimates throughout gestation correlate well with known fetal weight at these gestations. Relaxation time measurements also can be made in the placenta and lungs. By combining the changes in relaxation and volume with gestation in the future, it may be possible to develop an "index of maturity." This could be used to accurately reflect lung maturation. T1 and T2 parameters in the placenta decreased with gestational age and with abnormal placentation. EPI can be used to assess perfusion in the placenta and flow in the uterine arteries because of its rapid acquisition times. These techniques have been applied to assess perfusion within the fetal brain.

Echo-Planar Imaging↗