Search PubMed⌕ Search

PubMed · 10676894

1Alpha-hydroxyvitamin D3 prevents the decrease of bone mineral density in lactating beagles.

Abstract

We assessed the change of bone mineral density (BMD) in lactating beagles with dual energy X-ray absorptiometry (DXA) and the preventive effect of 1alpha-hydroxyvitamin D3 (1alpha(OH)D3) on the BMD. Beagles, two to five years old, were used for detecting the time course change of BMD. Since the coefficient of variation (CV(%)) on detecting lumber vertebral (L2-L4) and tibial BMD by DXA was about 0.5%, DXA was useful to detect the change of BMD in beagles. There was a marked decrease in vertebral BMD during lactational period in the control group. The BMD levels after weaning were found to reverse to the initial level at mating. The same tendency was observed in tibial BMD as vertebral BMD, though the BMD changes were not marked. Beagles were administered at a dose of 0.1 microg/kg of 1alpha(OH)D3 three times in a week, and it was found to suppress the decrease in vertebral BMD during the breast feeding period. Also, the administration of 1alpha(OH)D3 promoted the prevention of decreased BMD during lactation both in vertebrae and tibiae. Significant effects of 1alpha(OH)D3 administration on tibial BMD were not observed. No adverse effects, such as hypercalcemia and hypercalciuria, were observed during the experimental period. Therefore, DXA was useful for detecting the changes of BMD in lactating beagles and the change of BMD was marked in lumber vertebrae, which are rich in trabecular bone. The preventive effect of 1alpha(OH)D3 on the decrease of BMD during the lactation period was observed in beagles.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Ichikawa, K Katagiri, Y Higuchi, S Takeda, K Saito. 2000. 1Alpha-hydroxyvitamin D3 prevents the decrease of bone mineral density in lactating beagles.. https://doi.org/10.1292/jvms.62.75. https://searchpubmed.org/record/pubmed%3A10676894/1alpha-hydroxyvitamin-d3-prevents-the-decrease-of-bone-mineral-density-in-lactating-beagles

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗