MR hysterosalpingography: protocol development and refinement for simulating normal and abnormal fallopian tube patency--feasibility study with a phantom.

Abstract

PURPOSE: To develop and refine a pulse sequence and protocol for testing the feasibility of magnetic resonance (MR) hysterosalpingography in a phantom model. MATERIALS AND METHODS: A phantom simulating the uterus, fallopian tubes, and surrounding pelvic cavity was constructed. T2-weighted acquisition strategies-breath-hold fast spin-echo, rapid acquisition with relaxation enhancement (RARE), and haff-Fourier RARE-were refined to acquire sequential 70-mm coronal imaging volumes. Contrast agent was injected into the introducing catheter entering the os of the simulated uterus. Interacquisition interval, type of contrast agent (eg, sterile saline solution or water), and quantity of contrast agent (eg, 1-5 mL per acquisition) were varied. Digital image subtraction was used to enhance image quality. Images were qualitatively analyzed and rated good, fair, or poor for temporal resolution, spatial resolution, fallopian tube conspicuity, and free spill conspicuity. Once the technique was refine, the phantom was reconfigured to simulate unilateral and bilateral hydrosalpinx. RESULTS: The RARE sequence with an 8-second interacquisition interval and a 5-mL interacquisition of sterile water produced good images of the simulated fallopian tubes and free spill. Depiction of unilateral and bilateral hydrosalpinx was also reliably demonstrated. CONCLUSION: This study with a phantom model demonstrates the feasibility of MR hysterosalpingography to depict normal and diseased fallopian tubes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R E Frye, S M Ascher, D Thomasson. 2000. MR hysterosalpingography: protocol development and refinement for simulating normal and abnormal fallopian tube patency--feasibility study with a phantom.. https://doi.org/10.1148/radiology.214.1.r00ja42107

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Computed tomographic enterography adds information to clinical management in small bowel Crohn's disease.

BACKGROUND: CT enterography yields striking findings in the bowel wall in Crohn's disease. These images may help to evaluate whether small bowel narrowing results from active disease requiring anti-inflammatory therapy. However, the clinical relevance of these images is unknown. It is also not known if these radiologic findings correlate with objective biomarkers of inflammation. METHODS: In a blinded and independent evaluation, IBD subspecialty gastroenterologists reviewed clinical data, and CT radiologists reviewed CT enterography scans of 67 consecutive patients with Crohn's disease and suspicion of either small bowel inflammation or stricture. Comparisons were made between (1) clinical and radiologic assessments of inflammation and stricture, (2) clinical assessments before and after computed tomographic enterography (CTE) reports were revealed, and (3) radiologic findings and objective biomarkers of inflammation. RESULTS: (1) Individual CTE findings correlated poorly (Spearman's rho < 0.30) with clinical assessment; (2) clinicians did not suspect 16% of radiologic strictures, and more than half the cases of clinically suspected strictures did not have them on CTE; (3) CTE data changed clinicians' perceptions of the likelihood of steroid benefit in 41 of 67 cases; (4) specific CTE findings correlated with CRP, and a distinct set of CTE findings correlated with ESR in the subset of patients who had these biomarkers measured. CONCLUSIONS: CTE seems to add unique information to clinical assessment, both in detecting additional strictures and in changing clinicians' perceptions of the likelihood of steroids benefiting patients. The biomarker correlations suggest that CTE is measuring real biologic phenomena that correlate with inflammation, providing information distinct from that in a standard clinical assessment.

Constriction, Pathologic↗

Optimization of spatial resolution for peripheral magnetic resonance angiography.

RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.

Constriction, Pathologic↗