Orthodontic elastic materials.

Abstract

Latex elastics and synthetic elastomers have certain similarities and differences. In the fracture tests the latex elastics showed a greater amount of loss in strength than plastic elastomers when stretched over a 21 day period. There is a great variability, as much as 50%, in the tensile strength of the plastic materials taken from the same batch and stretched under the same conditions. The Ormco Power Chain was more resilient than the Unitek AlastiK chain. The Unitek AlastiKs had more force and stretched less. The force decay of synthetic elastomers, stretched over a specific length and time, exhibited a great loss in force. This loss could be as great as 73% during the first day. The decay of force continued at a slower rate during the rest of the 21 day period. Unitek AlastiK C2 double links, when stretched 17 millimeters, had a higher initial force averaging 641 grams (22.5 ounces) than the Ormco Power Chain which averages 342 grams (12.0 ounces). In one day the force was reduced to 171 grams (6.0 ounces) for both materials. The elastic materials within the same batch showed a great variation in the modulus of elasticity under different test conditions. The approximate force generated when stretched dry, within the elastic limit, was 22 grams per millimeter for 3/16 inches heavy latex elastics. The Unitek AlastiK C2 gave a force of 89 grams per millimeter, while the Ormco Power Chain had a value of 46 grams per millimeter. The modulus of elasticity of all of the materials was much lower after immersion in the water bath. The force decay under constant force application to latex, elastic, polymer chains, and tied loops showed that the greatest amount of force decay occurred during the first three hours in the water bath. The forces remained relatively the same throughout the rest of the test period. The elastic materials undergo permanent deformation in shape. The synthetic elastomers exhibited plastic deformation when the elastomers were stretched 17 millimeters for 21 days. In the dry condition the force decay was 63% for the Unitek chains and 42% for the Ormco Power Chain. The synthetic elastomers should be prestretched before being placed in the mouth. The elastomers should be used within their resilient ranges. Clinical treatment procedures should take into consideration the rapid initial force decay of elastic materials that occurs during the first day and the residual forces remaining.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A K Wong. 1976. Orthodontic elastic materials.. https://doi.org/10.1043/0003-3219(1976)046%3C0196%3Aoem%3E2.0.co%3B2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of osteonectin-derived peptide on the viscoelasticity of hydrogel/apatite nanocomposite scaffolds.

Hydrogel/apatite nanocomposites are the ideal biomaterial to mimic the physio-chemical and biologic properties of the bone and to fabricate scaffolds for bone regeneration. The objective of this work was to investigate the effect of an osteonectin derived glutamic acid sequence on the viscoelastic properties of poly(lactide-ethylene oxide-fumarate) (PLEOF)/apatite composite, as a model degradable material in bone regeneration. Osteonectin is an extracellular acidic glycoprotein of the bone matrix, which is believed to be involved in linking the collagen network to hydroxyapatite (HA), the mineral phase of the bone. We synthesized a 6-glutamic acid sequence in solid phase with affinity to HA crystals via ionic interactions. One end of the synthesized peptide was functionalized with an acrylate group to covalently attach the peptide (Ac-Glu6) to the aqueous-based biodegradable and in situ crosslinkable PLEOF hydrogel matrix. To determine the effect of energetic interactions between the fillers and hydrogel matrix, HA nanoparticles were also treated with an acrylate functionalized 6-glycine amino acid peptide (Ac-Gly6) that interacts with the fillers only by van der Waals and polar interactions (without ionic interactions). Crosslinked PLEOF/apatite scaffolds were prepared using PLEOF as the degradable macromer, HA nanofillers treated with Ac-Glu6 peptide linker, and a neutral redox initiation system. The viscoelastic properties were studied by dynamic time sweep, strain sweep, and small amplitude oscillatory rheometry. Composites without surface treatment, treated with Ac-Gly6, and treated with Ac-Glu6 at different volume fractions and various particle sizes were examined. The results showed that the 6-mer glutamic acid sequence significantly affects the shear modulus of the scaffold because of ionic interactions between the peptide and HA crystals.

Elasticity↗

Improvement of elastographic displacement estimation using a two-step cross-correlation method.

The cross-correlation algorithm used to compute the local strain components for elastographic imaging requires a minimum radio-frequency data segment length of around 10 wavelengths to obtain accurate and precise strain estimates with a reasonable signal-to-noise ratio. Shorter radio-frequency data segments generally introduce increased estimation errors as the information content in the data segment reduces. However, shorter data segments and increased overlaps are essential to improve the axial resolution in the strain image. In this paper, we propose a two-step cross-correlation technique that enables the use of window lengths on the order of a single wavelength to provide displacement and strain estimates with similar noise properties as those obtained with a 10 wavelength window. The first processing step utilizes a window length on the order of 10 wavelengths to obtain coarse displacement estimates between the pre- and post-compression radio frequency data frames. This coarse displacement is then interpolated and utilized as the initial guess-estimate for the second cross-correlation processing step using the smaller window. This step utilizes a single wavelength window to improve the axial resolution in strain estimation, without significantly compromising the noise properties of the image. Simulation and experimental results show that the signal-to-noise and contrast-to-noise ratio estimates improve significantly at the smaller window lengths with the two-step processing when compared with the use of a similar sized window in the currently utilized single window method.

Elasticity↗

Thermodynamics of ions and water transport in porous media.

The thermodynamic framework of Prigogine, de Groot, and Mazur is extended to study the transport of ions and water in thermoporoelastic materials assuming infinitesimal deformations. New expressions are developed for the first and second principles of nonequilibrium thermodynamics of multicomponent systems and a generalized power balance equation is derived. For porous materials, all the components cannot be treated on a symmetric basis. A Lagrangian framework associated with deformation of the solid phase is introduced and, in this framework, Curie's principle is used to set up the form of the linear constitutive equations describing the transport of ions, water, and heat through the pore network. The material properties entering these equations were recently obtained by Revil and Linde [J. Colloid Interface Science 302 (2006) 682-694] using a volume-averaging approach based in the Nernst-Planck and Stokes equations. This provides a way to relate the material properties entering the constitutive equations to two textural parameters characterizing the topology of the pore space of the material (namely the tortuosity of the pore space and the permeability). The generalized power balance equation is used to derive the linear poroelastic constitutive equations (including the osmotic pressure) to describe the reversible contribution of deformation of the medium in response to ions and water transport through the connected porosity.

Elasticity↗