Search PubMed⌕ Search

PubMed · 10616874

Maximum-likelihood reconstruction with ordered subsets in bone SPECT.

Abstract

UNLABELLED: This study was aimed at determining whether the ordered-subset expectation maximum (OSEM) is more effective than filtered backprojection (FBP) for bone SPECT in the routine clinical context. METHODS: Fifty-seven consecutive bone SPECT studies were analyzed. They included pelvic and lumbar spine, thoracolumbar spine, head and neck, feet and shoulders. A 64-projection SPECT study was acquired over 360 degrees by single-head cameras 2-3 h after the injection of 750 MBq 99mTc-methylene diphosphonate. Three observers compared the OSEM and FBP reconstructed images. RESULTS: Streak artifacts, always present with FBP, were rarely generated with the OSEM. When present (n = 24), artifacts associated with negative values near hyperactivities in FBP were not generated with the OSEM in 67% of the cases (n = 16), permitting a satisfactory interpretation of these regions. In half of the other cases (17%, n = 4/24), interpretation was precluded. In only one case did the three observers agree that more hyperactivities were seen with the OSEM. Ninety-six percent of the OSEM pictures were superior or equal to FBP for anatomic resolution and were clearly better in 12% of the cases. The extent of the lesion with the OSEM seemed better or equally defined in 96% and clearly better in 14% of the cases. The low-activity regions were better or equally visualized in all cases and were clearly better seen in 23% of the cases. The quality of the pictures was found to be better or superior with the OSEM in 98% of the cases and definitely better in 65% of the cases. CONCLUSION: Replacement of FBP by the OSEM in bone SPECT would be beneficial to clinical practice.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Blocklet, A Seret, N Popa, A Schoutens. 1999. Maximum-likelihood reconstruction with ordered subsets in bone SPECT.. https://pubmed.ncbi.nlm.nih.gov/10616874/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗