Operating room environment.

Abstract

Sepsis after total joint replacement is related directly to environmental contamination. Therefore, to control the source of environmental contamination, and ultimately sepsis, it must be realized that the operating room personnel are the major source of the bacteria as evidence by the rise in the colony forming units per square foot per hour from 13 units in an operating room without people to greater than 400 units during actual surgery. The use of inclusive gowns, such as hooded body exhaust, is most helpful. However, all operating room personnel including anesthesia personnel, circulating nurses, visitors, and the operating room team must wear inclusive gowns. Face masks and head covers offer no environmental protection. Some type of an environmental control, such as laminar airflow or ultraviolet light, is the most helpful with greater than 90% reduction of airborne bacteria at the wound and 60% reduction of airborne bacteria in the operating room. Therefore, to reduce environmental bacteria contamination the number of personnel in the operating room and the length of time for the actual surgery should be reduced, because wound contamination occurs first by direct fall out from the environment and second by contaminated equipment and gloved hands that initially were contaminated by the environment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M A Ritter. 1999. Operating room environment.. https://doi.org/10.1097/00003086-199912000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Contact stresses in the glenoid component in total shoulder arthroplasty.

Several studies of retrieved glenoid components from total shoulder arthroplasty show an erosion of the rim, surface irregularities, component fracture and wear resulting from polyethylene deformation in vivo. Particles resulting from polyethylene wear might be one of the reasons for the very high rate of glenoid component loosening found clinically. Because wear can be the result of high contact stresses, the aim of this study is to find out whether or not contact stresses are high enough to cause wear of the glenoid component and what influence the component type and geometry have on polyethylene contact stresses for different humerus abduction angles. Elasticity theory is used in a parametric study of contact stresses in several glenoid component designs. A finite element method is used to confirm the accuracy of the analytical solution. The analysis shows that the peak stress generated in glenoid components under conditions of normal living can be as high as 25 MPa; since this exceeds the polyethylene yield strength, wear and also cold flow of the components can be expected. It is predicted that more conforming components have lower contact stresses, which might result in lower wear rate and less cold flow. It is also found that a metal-backed component promotes higher contact stresses than an all-polyethylene component with the same total thickness, therefore it can be expected that metal-backed components have inferior wear properties.

Arthroplasty, Replacement↗

The new Frenchay artificial cervical joint: results from a two-year pilot study.

STUDY DESIGN: A clinical prospective observational cohort study of 15 patients undergoing cervical intervertebral disc replacement. OBJECTIVE: To assess the safety, clinical stability, and capacity of a newly designed cervical intervertebral disc replacement for preserving motion in the cervical spine of patients with degenerative disc disease. SUMMARY OF BACKGROUND DATA: Anterior cervical discectomy and interbody fusion results in loss of motion segments and there is evidence of accelerated degenerative changes occurring at adjacent levels. Intervertebral disc replacement may be a valid alternative to fusion. There is a need for cervical disc replacement to be evaluated in prospective studies before it can be adopted as an acceptable surgical technique. METHODS: The study enrolled 15 patients with cervical radiculopathy or myelopathy and radiologically confirmed cervical disc herniation or posterior vertebral body osteophytes. Eligibility for the study required that patients have either a previous adjacent-level surgical or congenital spinal fusion or radiologic evidence of adjacent-level degenerative disc disease. After decompressive surgery via an anterior approach, all 15 patients received the artificial joint. Follow-up visits were at set intervals and included clinical examination, radiologic assessment, and evaluation by patient-completed questionnaires. RESULTS: In all cases, the artificial joint maintained motion at the operative levels while reestablishing intervertebral height. The procedure was considered safe for experienced spine surgeons to perform, and the device was stable, with no dislocation of components or backing out of screws. Two screws broke, but without any consequence. Improvements in assessment scores were noted. CONCLUSIONS: Cervical intervertebral motion can be maintained with the new device, which is clinically stable. Meticulous attention must be paid to the surgical technique to maximize the chances of a good result. The pilot study was successful, although it has yet to be determined what conditions will benefit most from this technology.

Arthroplasty, Replacement↗