Search PubMed⌕ Search

PubMed · 10607804

Biological quality control for exercise testing.

Abstract

BACKGROUND: A study was undertaken to evaluate the use of a biological quality control programme for a computer controlled, breath-by-breath exercise test system over a 2.5 year period. METHODS: One healthy volunteer performed a regular progressive treadmill test with breath-by-breath measurements of oxygen uptake (VO(2)), carbon dioxide output (VCO(2)), ventilation (VE), and the ECG heart rate (HR). Following a familiarisation period, five consecutive tests were performed and the measurements at peak exercise were averaged to give baseline values. All tests were compared with these values. RESULTS: A total of 35 tests were recorded. The within subject standard deviation for measurements at peak exercise were 52 ml/min for VO(2), 74 ml/min for VCO(2), 3.1 l/min for VE, and 3 beats/min for HR. The mean (SE) percentage variation in measurements at peak exercise compared with the baseline values was +0.37 (0.30)% for VO(2), -0.10 (0.39)% for VCO(2), -0.88 (0.52)% for VE, and +1.2 (0.26)% for HR. The variability present in measurements made during high and moderate intensity exercise (73% VO(2)peak) was not significantly different (p>0.05). During the study period the quality control detected a fault on the oxygen analyser which was not apparent from the automatic calibration. CONCLUSIONS: Regular quality control using a healthy volunteer allows all components of the breath-by-breath system to be checked simultaneously and in a manner which is consistent with its clinical use. This practice can highlight faults not detected by automatic calibration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S M Revill, M D Morgan. 2000. Biological quality control for exercise testing.. https://doi.org/10.1136/thorax.55.1.63

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of free sulfite in wine by zone electrophoresis with isotachophoresis sample pretreatment on a column-coupling chip.

This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.

Calibration↗

Identification and characterization of Se-methyl selenomethionine in Brassica juncea roots.

The present work shows the identification and characterization of Se-methyl selenomethionine (SeMMet) as an important Se species in Brassica juncea roots when grown in the presence of Se-methionine (SeMet) as the Se source. SeMMet was isolated by liquid chromatography employing two different liquid chromatographic mechanisms: reversed-phase ion-pairing using heptafluorobutyric acid as counter ion and cation exchange using a pyridinium formate gradient (pH 3). Inductively coupled plasma mass spectrometry was used for the detection of Se. SeMMet was characterized by electrospray quadrupole time-of-flight MS in both a synthesized standard and in the roots extract using collision-induced dissociation of the selected ion. Preliminary evidence suggests that Brassica juncea may also produce dimethylselenonium propionate, although to a much lesser extent.

Calibration↗

Influence of the extraction mode on the yield of some furanocoumarins from Pastinaca sativa fruits.

Analysis of plant material is an important task in chemotaxonomical investigations, in search of plants with pharmacological activity or in standardisation of plant drugs. The choice of optimal conditions for the analysis of plant material and effect of extraction method on the yield of furanocoumarins from Pastinaca sativa fruits were examined. The following extraction methods were used in experiments: exhaustive extraction in Soxhlet apparatus, ultrasonification (USAE) at 25 and 60 degrees C, microwave-assisted solvent extraction in open and closed system (MASE) and accelerated solvent extraction (ASE). In most cases, the yield of furanocoumarins was highest by use of ASE method as well as by ultrasonification at 60 degrees C.

Calibration↗