Search PubMedSearch

PubMed · 1060467

A method for sharpening probes.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W P Crocker. 1975-12-16. A method for sharpening probes.. https://doi.org/10.1038/sj.bdj.4803669

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Innovative uses for hypodermic needles in endodontics.

Hypodermic needles have sharp cutting edges along their bevels. These can be used to enlarge canal openings and to cut around a broken instrument or other object to be removed. Means of attaching the needle to such foreign objects for removal are discussed.

Dental Instruments

An in vitro assessment of the dentine lost during instrumentation using the Periosonic system.

This study investigated the ability of a new instrument designed for root debridement, the Periosonic, to remove dentine compared to a hand curette and an ultrasonic scaler. The Periosonic system is a modification of the Micro-Megax endodontic system and uses modified files to remove plaque, calculus and tooth substance. The Periosonic has 2 file types; the Periosonic 1 is a more aggressive file for the removal of gross supra- and subgingival deposits, while the Periosonic 2 is a thinner more flexible file used for the removal of subgingival deposits. 40 human dentine specimens were ground flat and baseline measurements were made using a surfometer. The specimens were divided into 4 experimental groups and each group was treated with a hand curette, ultrasonic scaler, Periosonic 1 or 2 using 12, 1-s strokes. The specimens were remeasured blind in the surfometer. The curette removed 23.6 microm of dentine, the ultrasonic 6.8 microm, the Periosonic 1 18.8 microm and the Periosonic 2 12.5 microm. A qualitative assessment of the samples following mechanical preparation was also made. In conclusion, the Periosonic instrument does not remove more tooth substance than a conventional curette and may be a useful addition for the debridement of root surfaces.

Dental Instruments

A SEM study of in vivo accuracy of the Root ZX electronic apex locator.

Twenty-nine unprepared, vital teeth were used to evaluate the accuracy of the Root ZX in locating the root canal foramen. After extraction of the teeth, a scanning electron microscope analyzed the relation of the file tip to the foramen. The sample was divided into two groups (Group A and Group B) according to the presence of a normal apical foramen (along the root main axis) or of a lateral foramen (deviating from the root main axis). With a tolerance level of +/- 0.5 mm, a clinical accuracy rate of 82.75% was recorded in the total sample. With a +/- 1.0-mm tolerance level, an accuracy of 100% was found. The error in locating the apex was significantly smaller in cases with a normal apical foramen (Group A) than in cases with a lateral foramen (Group B) (p < 0.001). An accuracy of 100% at the +/- 0.5-mm tolerance level was registered in Group A.

Dental Instruments