Search PubMedSearch

PubMed · 10547521

Digital imaging update.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Abelson. 1999. Digital imaging update.. https://doi.org/10.1016/s0889-5406(99)70001-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Visual and colorimetric lithium ion sensing based on digital color analysis.

A new optical analytical method, "Digital Color Analysis (DCA)", is proposed based on a digital color analyzer instead of the conventional optical methodology, "Spectrophotometry". The digital color analyzer is a hand-held-size instrument for measuring "colors", and it can transform the color information into numerical values, color library data, etc., that can be treated as analytical information. DCA gives us a more informative analytical method than spectrophotometry by treating colors as digital information. In addition, DCA can also simulate the optimum color variations for optimization of the visual sensor with computer assistance. By utilizing colors as digital information, colorimetric analysis that has been used for only semiquantitative analysis can serve as an accurate determination method. On the basis of DCA, we developed a plasticized PVC film optode and a paper optode for Li+ determination in saliva. After the optimization of color variation and the detection range for the Li+ measurements, the optode membrane gives colorless gray in the Li+ therapeutic range (at 10(-3) M) in saliva. Consequently, whether or not the optimum therapeutic Li+ concentration is maintained can be easily evaluated with these optodes. Especially, the sensing paper optode can be easily handled within a short measurement time (approximately 80 s) which is suitable for home use. Using the digital color analyzer with QxQy coordinates, a linear relation calibration curve can be obtained over the range from 10(-5) to 10(-1) M Li+, in which the analyzer can detect a concentration difference of approximately 0.1 mM Li+. For the near future, an accurate and simple analysis is needed for a health check at home that does not require going to a hospital. The optode based on DCA has great potential for this analytical purpose.

Analog-Digital Conversion

A robotic system for blood sampling.

A robotic system to take blood samples autonomously from the forearm is presented and preliminary results are discussed which demonstrate its feasibility. Force/position profiles, while pressing a flat-headed probe against the surface of the skin, enable the determination of a vein's location to within 1 mm on a phantom. When a needle is inserted, the characteristic force/position profile, on puncturing the vein wall, is distinctive enough to implement automatic needle withdrawal to prevent overshoot. Future developments of the project are presented that provide both an autonomous blood sampling robot and a force-feedback surgical trainer.

Analog-Digital Conversion

A simple, PC-dedicated, implanted digital PIM radiotelemetric system.

The short-distance, PC-dedicated implanted telemetry system is described. Schematic drawings of the transmitter and Centronics port interface are given and the main problems of the controlling program are discussed. The interface can be easily converted to serve as an analog output and the method of adaptation is demonstrated. The whole system was tested in animal experiments with two different amplifiers and the examples of resulting direct ECG and both direct and integrated intestinal EMG recordings are included.

Analog-Digital Conversion