Search PubMed⌕ Search

PubMed · 10410813

[Coronary microcirculation. Physiologic and pathologic aspects].

Abstract

The coronary circulation has a protective regulation system which, in extreme haemodynamic conditions, compensates increased myocardial oxygen demand. The coronary reserve, based on this concept defines the capacity of the system to increase flow temporally, and, thereby, myocardial oxygen supply. The introduction of new methods of investigating the coronary microcirculation has enabled the study of this phenomenon in several cardiovascular pathologies. Two types of investigation are used currently for studying the coronary microcirculation: 1) invasive methods, especially the recently developed intracoronary Doppler and pressure guide, 2) non-invasive methods, and, in particular, contrast echocardiography, position emission tomography and magnetic nuclear resonance. These investigations allow measurement of the coronary reserve or the assessment of the myocardial consequences of abnormalities of the microcirculation. Some workers use these methods to investigate pathological coronary microcirculation in different cardiomyopathies, in the presence of different cardiovascular risk factors (hypertension, diabetes, smoking, hypercholesterolaemia) and after cardiac transplantation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Garot, E Teiger, P Dupouy, E Aptecar, L Hittinger, J L Dubois-Randé. 1999. [Coronary microcirculation. Physiologic and pathologic aspects].. https://pubmed.ncbi.nlm.nih.gov/10410813/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries.

BACKGROUND: In-stent restenosis by excessive intimal hyperplasia reduces the long-term clinical efficacy of coronary stents. Because shear stress (SS) is related to plaque growth in atherosclerosis, we investigated whether variations in SS distribution are related to variations in neointima formation. METHODS AND RESULTS: In 14 patients, at 6-month follow-up after coronary Wallstent implantation, 3D stent and vessel reconstruction was performed with a combined angiographic and intravascular ultrasound technique (ANGUS). The bare stent reconstruction was used to calculate in-stent SS at implantation, applying computational fluid dynamics. The flow was selected to deliver an average SS of 1.5 N/m(2). SS and neointimal thickness (Th) values were obtained with a resolution of 90 degrees in the circumferential and 2.5 mm in the longitudinal direction. For each vessel, the relationship between Th and SS was obtained by linear regression analysis. Averaging the individual slopes and intercepts of the regression lines summarized the overall relationship. Average Th was 0.44+/-0.20 mm. Th was inversely related to SS: Th=(0.59+/-0.24)-(0.08+/-0.10)xSS (mm) (P<0.05). CONCLUSIONS: These data show for the first time in vivo that the Th variations in Wallstents at 6-month follow-up are inversely related to the relative SS distribution. These findings support a hemodynamic mechanism underlying in-stent neointimal hyperplasia formation.

Coronary Circulation↗

Rapid ventricular assessment using real-time interactive multislice MRI.

A multislice real-time imaging technique is described which can provide continuous visualization of the entire left ventricle under resting and stress conditions. Three dynamically adjustable slices containing apical, mid, and base short axis views are imaged 16 times/sec (48 images/sec), with each image providing 3.12 mm resolution over a 20 cm field of view. Initial studies indicate that this technique is useful for the assessment of LV function by providing simultaneous real-time visualization of all 16 wall segments. This technique may also be used for stress LV function and, when used in conjunction with contrast agents, myocardial perfusion imaging. Magn Reson Med 45:371-375, 2001.

Coronary Circulation↗

Flow wire measurements after complete arterial coronary revascularization with T-grafts.

BACKGROUND: The T-graft procedure achieves complete arterial revascularization in coronary three-vessel disease. In this technique, all bypass anastomoses are supplied by the left internal mammary artery (IMA). This prospective study explores the question of whether the quantitative flow in such grafts is influenced by the pathology in the native coronary arteries. METHODS: Eighty-two patients with coronary three-vessel disease were studied after complete arterial coronary revascularization with T-grafts. Quantitative flow and coronary flow reserve were measured in the proximal IMA with a Doppler guide wire. Three groups were compared: group 1, all native coronary arteries were stenosed but patent (n = 31); group 2, one occluded native coronary vessel (n = 33); group 3, two or more occluded native coronary arteries (n = 18). RESULTS: Quantitative flow was significantly higher in group 3 than in group 2 at 1 week (93.9 +/- 39.5 vs 75.8 +/- 27.3 mL/min, p < 0.05) and 6 months postoperatively (86.0 +/- 40.1 vs. 69.1 +/- 35.5 mL/min, p < 0.05). Flow in group 2 was significantly (p < 0.05) higher than in group 1 (1 week: 58.0 +/- 28.4 mL/min, 6 months: 55.2 +/- 29.2 mL/min) in both examinations. There were no significant differences in coronary flow reserve between the three groups (1: 2.88 +/- 0.97, 2: 2.84 +/- 0.96, 3: 2.74 +/- 0.94). CONCLUSIONS: After complete arterial revascularization with T-grafts, the quantitative flow in the IMA is influenced by the status of the native coronary arteries. As a result of competitive flow phenomena, blood flow in the bypasses is significantly lower when the coronary arteries are affected only by stenosis.

Coronary Circulation↗