Search PubMed⌕ Search

PubMed · 10407730

[Validating a 7-channel ambulatory polygraph unit. 2: Simultaneous polysomnography].

Abstract

PURPOSE: For some time, the ambulatory diagnosis of respiratory disturbances during sleep has included the use of seven-channel recording units. One of these systems is the POLY-MESAM unit (MAP, Germany). METHODS: The aim of the present study was to validate the POLY-MESAM system by simultaneously performing 12-channel polysomnography. Forty-nine patients (45 males and 4 females) with different severities of obstructive sleep-related breathing disorders were included. Obstructive sleep apnea was diagnosed, when an apnea-hypopnea index (AHI) > 15 was found by polysomnography. The sensitivity and specificity for POLY-MESAM were calculated on the basis of the polysomnographic AHI. RESULTS: The sensitivity of POLY-MESAM for detecting patients with an AHI > 15 was 86.4% and the specificity was 100%. CONCLUSIONS: The POLY-MESAM system was easy to use. The sensitivity and specificity for the MESAM4 unit were 92% and 97% respectively, which was similar to POLY-MESAM. Additionally, POLY-MESAM provided the possibility for distinguishing the different kinds of apneas. Thus, POLY-MESAM was considered to be a useful development of the previous MESAM4 unit. In some cases, use of the POLY-MESAM unit resulted in underestimation of the AHI. POLY-MESAM produced false-negative results in patients with mild to moderate OSA. This finding was reflected in the relatively poorer sensitivity of the method (86.4%). Cardiorespiratory sleep studies (as possible with POLY-MESAM) are best limited to patients for whom the diagnosis of OSA is highly probable or as a follow-up tool in selected circumstances.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Verse, W Pirsig, B Junge-Hülsing, B Kroker. 1999. [Validating a 7-channel ambulatory polygraph unit. 2: Simultaneous polysomnography].. https://pubmed.ncbi.nlm.nih.gov/10407730/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗