An electrically isolated balanced wideband current source: basic considerations and design.

Abstract

At relatively high frequencies, the application of an alternating current through the body or a body segment results in electromagnetic stray fields which reduce the amount of current actually injected into the tissue under study. This radiation effect can be reduced by use of a symmetrical configuration current source. The symmetry of such an arrangement, however, depends on the stray capacitances of the source with respect to surrounding equipment. To minimise these effects, it is required that the source is electrically isolated from the surrounding equipment and the subject under study. In this manner stray capacitances with respect to elements of the current source are reduced. In such a configuration common mode voltages to the input amplifier of the measuring system are also reduced. The paper describes design considerations and the implementation of a wideband current source capable of injecting alternating current in the order of 300 microARMS into biological tissue having impedances up to 1 k omega. Current stabilisation is obtained by means of a control circuit which measures the actual current passing through the tissue under study. Leakage currents arising from shielding and stray capacitances are compensated for. The usable frequency range is between 4 kHz and 1024 kHz and current stability is better than 0.2%. Through the use of a symmetrical, floating circuit a configuration is obtained which substantially reduces stray effects. The current source is connected to other circuits by means of two isolation ports: (1) a transformer coupling for the carrier frequency; and (2) an opto-coupler to transfer a phase reference signal obtained from current measurement. The current amplitude can be modulated by controlling the reference input to the control loop by means of a third auxiliary isolation port for transfer of the modulating signal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H G Goovaerts, T J Faes, E Raaijmakers, R M Heethaar. 1998. An electrically isolated balanced wideband current source: basic considerations and design.. https://doi.org/10.1007/bf02524430. https://searchpubmed.org/record/pubmed%3A10367444/an-electrically-isolated-balanced-wideband-current-source-basic-considerations-and-design

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Bioelectricity.

Explore the source record for details and available documents.

Cardiography, Impedance↗

Bioimpedance to prevent heart failure hospitalization.

Transthoracic and whole-body bioimpedance monitoring has been commercially available for years; however, attention to its use as a diagnostic and event-monitoring modality has not been routinely applied in patients with heart failure (HF). In 2005, intrathoracic bioimpedance monitoring via an implantable cardioverter defibrillator brought new awareness of bioimpedance technology. In addition, new knowledge about congestion in HF, including length of time a patient is congested before seeking emergency care, lack of sensitivity of common signs and symptoms used to monitor congestion and diagnose HF exacerbation, and poor clinical outcomes when hypervolemia is present, heightened the need for more aggressive assessment and management. Bioimpedance device monitoring provides data needed to make treatment decisions that promote euvolemia and optimal cardiac performance. This review summarizes three options for measurement of bioimpedance hemodynamic data, discusses its use in preventing HF hospitalization, and describes issues that need to be overcome before bioimpedance monitoring can be routinely used in HF management.

Cardiography, Impedance↗

Fetuses with congenital heart disease demonstrate signs of decreased cerebral impedance.

OBJECTIVE: The purpose of this study was to determine whether fetuses with a congenital heart defect demonstrate changes in cerebrovascular impedance. STUDY DESIGN: Fetal echocardiograms from January 2001 to May 2005 were reviewed. Cases had sonographically diagnosed congenital heart defects; control subjects were gestational age-matched fetuses with normal echocardiograms. The pulsatility index in the middle cerebral artery was used to measure impedance to cerebral blood flow. Abnormal middle cerebral artery pulsatility index was defined as less than the 5th percentile. Cases were subgrouped into mixing versus nonmixing lesions. RESULTS: Of 142 total fetuses, there were significantly more abnormal middle cerebral artery pulsatility indices in the cases (5/71) than in the control subjects (0/71; P = .023); all abnormal middle cerebral artery pulsatility indices occurred in the fetuses with admixing cardiac lesions. CONCLUSION: Fetuses with congenital heart defect are significantly more likely to have decreased cerebrovascular impedance. This may represent a marker of cerebral hypoxemia that is due to intracardiac mixing of oxygenated and deoxygenated blood. Theoretically, this hypoxemia may contribute to the cause of abnormal neurologic development in these infants.

Cardiography, Impedance↗