An electrically isolated balanced wideband current source: basic considerations and design.

Abstract

At relatively high frequencies, the application of an alternating current through the body or a body segment results in electromagnetic stray fields which reduce the amount of current actually injected into the tissue under study. This radiation effect can be reduced by use of a symmetrical configuration current source. The symmetry of such an arrangement, however, depends on the stray capacitances of the source with respect to surrounding equipment. To minimise these effects, it is required that the source is electrically isolated from the surrounding equipment and the subject under study. In this manner stray capacitances with respect to elements of the current source are reduced. In such a configuration common mode voltages to the input amplifier of the measuring system are also reduced. The paper describes design considerations and the implementation of a wideband current source capable of injecting alternating current in the order of 300 microARMS into biological tissue having impedances up to 1 k omega. Current stabilisation is obtained by means of a control circuit which measures the actual current passing through the tissue under study. Leakage currents arising from shielding and stray capacitances are compensated for. The usable frequency range is between 4 kHz and 1024 kHz and current stability is better than 0.2%. Through the use of a symmetrical, floating circuit a configuration is obtained which substantially reduces stray effects. The current source is connected to other circuits by means of two isolation ports: (1) a transformer coupling for the carrier frequency; and (2) an opto-coupler to transfer a phase reference signal obtained from current measurement. The current amplitude can be modulated by controlling the reference input to the control loop by means of a third auxiliary isolation port for transfer of the modulating signal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H G Goovaerts, T J Faes, E Raaijmakers, R M Heethaar. 1998. An electrically isolated balanced wideband current source: basic considerations and design.. https://doi.org/10.1007/bf02524430

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reproducibility of impedance cardiography parameters in outpatients with clinically stable coronary artery disease.

BACKGROUND: Impedance cardiography (ICG) is a noninvasive method of determining hemodynamic parameters. It is clinically important to determine whether any change in ICG parameters occur due to changes in disease status or therapeutic interventions, or due to normal hemodynamic and technology variability. The objective of this study was to establish the intra- and inter-day reproducibility of ICG in a stable population with coronary artery disease (CAD). METHODS: A prospective, time series design was used. The study group consisted of 96 clinically stable CAD patients in an outpatient cardiac rehabilitation program. Measurements of ICG hemodynamic parameters were obtained at four points in time: after 5 and 10 min of rest on the first day and after 5 and 10 min of rest on a second day, 1 week later. RESULTS: There were small but significant intra-day changes between the 5- and 10-min hemodynamic measures. Mean absolute percent changes in intra-day hemodynamic measures were <8%. High intra-day correlation was observed, ranging from 0.85 for mean arterial pressure to 0.99 for thoracic fluid content. There were expectedly larger inter-day hemodynamic variation of up to 18% and lower inter-day correlation for all ICG parameters ranging from 0.66 to 0.88. CONCLUSIONS: Impedance cardiography measurements demonstrate both intra- and inter-day reproducibility within clinically acceptable ranges in a clinically stable population of CAD patients. The expected ranges of variation can be used to gauge whether a patient's hemodynamic status has changed because of disease or intervention.

Cardiography, Impedance↗

Hypertension as a hemodynamic disease: the role of impedance cardiography in diagnostic, prognostic, and therapeutic decision making.

Hypertension is the most common cardiovascular disease, affecting approximately 60 million Americans. Despite the importance of this condition, only the minority of patients are appropriately identified and treated to reach recommended blood pressure (BP) goals. Although historically defined as an elevation of BP alone, hypertension is characterized by abnormalities of cardiac output, systemic vascular resistance, and arterial compliance. These hemodynamic aspects of hypertension have implications for diagnosis, risk stratification, and treatment. Impedance cardiography (ICG) has emerged as a unique and highly accurate noninvasive tool that is used to assess hemodynamic parameters. Measurement of the various hemodynamic components using ICG in those with hypertension allows more complete characterization of the condition, a greater ability to identify those at highest risk, and allows more effectively targeted drug management. This article reviews the importance of hemodynamic factors in hypertension and the evolving role of ICG technology in the assessment and management of this important cardiovascular condition.

Cardiography, Impedance↗