Search PubMed⌕ Search

PubMed · 1034915

A continuous-flow, variable mixing valve for perfusion experiments.

Abstract

The device described here continuously mixes two solutions in any required ratio and has been used at flow rates of 6 ml/min in tissue perfusion experiments. Its low-cost construction consists of a three-way miniature solenoid valve driven by a simple electronic circuit. Mixing is stable, reproducible and accurate to +/- 1% of dial setting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D L Cook, D E Hokanson. 1976-12-28. A continuous-flow, variable mixing valve for perfusion experiments.. https://doi.org/10.1007/bf00585158

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A 1.48-mW low-phase-noise analog frequency modulator for wireless biotelemetry.

This paper presents a low-phase-noise, hybrid LC-tank, analog frequency modulator for wireless biotelemetry employing on-chip NMOS varactors in the inversion region as the frequency tuning element. We demonstrate that a correct estimate for the destination signal-to-noise ratio, which quantifies the quality of the wirelessly received signal in a frequency-modulated biotelemetry system, is only achieved after taking into account the large-signal oscillation effect on the tank varactor. A prototype chip is fabricated using AMI 1.5-microm double-poly double-metal n-well CMOS process, and exhibits a measured gain factor of 1.21 MHz/V in the mid-range of the tuning voltage and a phase noise of -88.6 dBc/Hz at 10-kHz offset from the 95.1-MHz carrier while dissipating 1.48 mW from a 3 V power supply leading to a figure of merit (FOM) of -166.5 dBc/Hz. The VCO is successfully interfaced with a penetrating silicon microelectrode with 700 microm2 iridium recording sites for wireless in vitro recording of a 50 Hz simulated normal sinus rhythm signal from saline over a distance of approximately 0.25 m. Given a typical gain of approximately 40 dB for fully integrated front-end bioamplifiers, a wireless recording microsystem employing this VCO would be capable of detecting input biopotentials down to the submilivolt range.

Electronics, Medical↗

A 2-D motion detection model for low-cost embedded reconfigurable I/O devices.

A low-cost reconfigurable embedded apparatus for two-dimensional (2-D) motion detection has been developed. This paper briefly outlines the embedded reconfigurable system architecture, and presents in-depth the 2-D motion detection model, which is directly mapped to reconfigurable hardware. Emphasis is placed on the hardware ability to adapt to individual needs of kinetically challenged persons by altering detection thresholds and delays, thus resulting into an efficient low-cost reconfigurable hardware implementation of the model. This paper also presents how the model detects complex motions through a vocabulary of simple motions, and how the system is trained to individual users' needs. Experimental results and integrated applications of the model for text processing are also presented.

Electronics, Medical↗