[Quality control in bone densitometry].

Abstract

Bone densitometry is a biological measurement which must comply to the usual rules of quality control. Calibration phantoms are available and must be regularly measured. Results may be interpreted by visual inspection or by estimating drift percentage. Different calculation methods have been proposed. A rigorous procedure is required when replacing densitometry devices. Simple and regular controls can assure the reliability of the technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Kolta, C Roux. 1999. [Quality control in bone densitometry].. https://pubmed.ncbi.nlm.nih.gov/10209705/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of bone mineral density of lumbar spine and whole body in low-birth-weight infants: comparison of two methods.

In the present study, we compared lumbar spinal and whole-body bone mineral density (BMD) measurements to determine which is more suitable for evaluating the bone mineral status of low-birth-weight (LBW) infants. Lumbar spinal and whole-body BMD were assessed simultaneously in a prospective series including 152 Japanese LBW infants (birth weight 453-2400 g, gestational age 24-38 weeks) from the age of 40 weeks post-conception to 2 years of age. Lumbar spinal BMD at 40 weeks post-conception was significantly correlated with birth weight (r = 0.74; P < 0.0001), but wholebody BMD was not correlated with birth weight. No correlation was found between lumbar spinal and whole-body BMD at 40 weeks post-conception. However, after 40 weeks post-conception, a significant correlation was found between lumbar spinal and whole-body BMD (r = 0.65; P < 0.0001). For infants with a body weight of 4 kg or less at the time of measurement, no correlation was found between lumbar spinal and whole-body BMD. However, for infants with a body weight above 4 kg, a significant correlation was found between lumbar spinal and whole-body BMD (r = 0.65; P < 0.0001). Thus, lumbar spinal BMD is more suitable than whole-body BMD for evaluation of the bone mineral status of LBW in early infancy. Therefore, lumbar spinal BMD should be used for serial evaluation of changes in the bone mineral status of LBW infants.

Absorptiometry, Photon↗

Endothelial nitric oxide synthase gene-deficient mice demonstrate marked retardation in postnatal bone formation, reduced bone volume, and defects in osteoblast maturation and activity.

Nitric oxide (NO) has been implicated in the local regulation of bone metabolism. However, the contribution made by specific NO synthase (NOS) enzymes is unclear. Here we show that endothelial NOS gene knockout mice (eNOS-/-) have marked abnormalities in bone formation. Histomorphometric analysis of eNOS-/- femurs showed bone volume and bone formation rate was reduced by up to 45% (P: < 0.01) and 52% (P: < 0.01), respectively. These abnormalities were prevalent in young (6 to 9 weeks old) adults but by 12 to 18 weeks bone phenotype was restored toward wild-type. Dual energy X-ray absorptiometry analysis confirmed the age-related bone abnormalities revealing significant reductions in femoral (P: < 0.05) and spinal bone mineral densities (P: < 0.01) at 8 weeks that were normalized at 12 weeks. Reduction in bone formation and volume was not related to increased osteoclast numbers or activity but rather to dysfunctional osteoblasts. Osteoblast numbers and mineralizing activity were reduced in eNOS-/- mice. In vitro, osteoblasts from calvarial explants showed retarded proliferation and differentiation (alkaline phosphatase activity and mineral deposition) that could be restored by exogenous administration of a NO donor. These cells were also unresponsive to 17ss-estradiol and had an attenuated chemotactic response to transforming growth factor-beta. In conclusion, eNOS is involved in the postnatal regulation of bone mass and lack of eNOS gene results in reduced bone formation and volume and this is related to impaired osteoblast function.

Absorptiometry, Photon↗

Dosimetry of rotational partial-skin electron irradiation.

BACKGROUND AND PURPOSE: Often, the most appropriate treatment for superficially and extensively spreading tumors of the skin is to use electron irradiation at enlarged distances. Rotational skin electron irradiation is a proven method for the treatment of the entire skin surface. We here report modifications of this technique in the set-up of partial-skin electron irradiation and the results of dosimetric examinations with regard to optimal shielding, dose profiles and depth dose curves under various irradiation conditions. MATERIALS AND METHODS: Irradiation was performed using electron beams with nominal energies of 6 MeV from a linear accelerator. The phantom was located on a rotating platform at a source-surface distance SSD=300 cm. A horizontal slit aperture (height: 32 cm) within a 2 cm thick polymethylmethacrylate (PMMA) shielding plate near the phantom was used to define the size of the irradiated region. Influences on dose distributions due to scattering processes on the PMMA edges were investigated using a flat ionization chamber and films. Absolute dose measurements and film calibration were made with the flat chamber. The quality of bremsstrahlung radiation behind the shielding was determined with a thimble ionization chamber in the phantom. RESULTS AND CONCLUSIONS: The results of rotational partial-skin electron irradiation reveal some of the investigated shielding geometries to be optimal. Depth dose distributions and dose rates correspond to the results obtained in total skin electron rotational irradiation. It is possible to apply the dose superficially in the first millimeters of the skin; the dose maximum is located at a depth of 0-2 mm, the 80% isodose at 9 mm. The amount of bremsstrahlung contamination is 2.5%. The local amount of absorbed dose per monitor unit depends strongly on patient/phantom cross-section geometry. At our institute, rotational partial-skin electron irradiation was implemented into clinical routine in 1997.

Absorptiometry, Photon↗