Tomotherapy.

Abstract

Tomotherapy is delivery of intensity-modulated, rotational radiation therapy using a fan-beam delivery. The NOMOS (Sewickley, PA) Peacock system is an example of sequential (or serial) tomotherapy that uses a fast-moving, actuator-driven multileaf collimator attached to a conventional C-arm gantry to modulate the beam intensity. In helical tomotherapy, the patient is continuously translated through a ring gantry as the fan beam rotates. The beam delivery geometry is similar to that of helical computed tomography (CT) and requires the use of slip rings to transmit power and data. A ring gantry provides a stable and accurate platform to perform tomographic verification using an unmodulated megavoltage beam. Moreover, megavoltage tomograms have adequate tissue contrast and resolution to provide setup verification. Assuming only translational and rotational offset errors, it is also possible to determine the offsets directly from tomographic projections, avoiding the time-consuming image reconstruction operation. The offsets can be used to modify the leaf delivery pattern to match the beam to the patient's anatomy on each day of a course of treatment. If tomographic representations of the patient are generated, this information can also be used to perform dose reconstruction. In this way, the actual dose distribution delivered can be superimposed onto the tomographic representation of the patient obtained at the time of treatment. The results can be compared with the planned isodose on the planning CT. This comparison may be used as an accurate basis for adaptive radiotherapy whereby the optimized delivery is modified before subsequent fractions. The verification afforded tomotherapy allows more precise conformal therapy. It also enables conformal avoidance radiotherapy, the complement to conformal therapy, for cases in which the tumor volume is ill-defined, but the locations of sensitive structures are adequately determined. A clinical tomotherapy unit is under construction at the University of Wisconsin.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T R Mackie, J Balog, K Ruchala, D Shepard, S Aldridge, E Fitchard, P Reckwerdt, G Olivera, T McNutt, M Mehta. 1999. Tomotherapy.. https://doi.org/10.1016/s1053-4296(99)80058-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The next generation.

Explore the source record for details and available documents.

Dose Fractionation, Radiation↗

Effect of incomplete repair on normal tissue complication probability in the spinal cord.

PURPOSE: To incorporate the effects of repair into a model for normal tissue complication probability (NTCP) in the spinal cord. METHODS AND MATERIALS: We used an existing model of NTCP for the spinal cord, based on a critical volume concept, into which we incorporated an incomplete repair (IR) scheme. Values for the repair half time were taken from existing experimental data. Repair corrections were expanded to account for the possibility of biphasic repair, namely the existence of long and short components of repair. RESULTS: We found that the model predicts complete repair to occur at approximately 15 hours, consistent with experimental data. The dependence of the model on the value of the dose per fraction was also studied. It was found that there is a sparing effect as the dose per fraction is decreased below 2 Gy. Surface plots of the NTCP as a function of both the interfraction interval (IFI) and the dose per fraction were generated. We investigated "iso-NTCP" curves, which may allow freedom in choice of treatment plans in terms of the optimal IFI and dose per fraction. As for biphasic repair, as the relative weights of the long and short components of repair were varied, the NTCP changed as well. The model showed little difference between mono- and bi-exponential repair in the time to complete repair, due to a dominance of the long component at long IFIs. CONCLUSIONS: Incorporating IR into NTCP modeling of the spinal cord is consistent with current experimental data. The concept of iso-NTCP curves is an approach which may be clinically useful.

Dose Fractionation, Radiation↗

Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers.

PURPOSE: The dose distributions of intensity-modulated radiotherapy (IMRT) treatment plans can be shown to be significantly superior in terms of higher conformality if designed to simultaneously deliver high dose to the primary disease and lower dose to the subclinical disease or electively treated regions. We use the term "simultaneous integrated boost" (SIB) to define such a treatment. The purpose of this paper is to develop suitable fractionation strategies based on radiobiological principles for clinical trials and routine use of IMRT of head and neck (HN) cancers. The fractionation strategies are intended to allow escalation of tumor dose while adequately sparing normal tissues outside the target volume and considering the tolerances of normal tissues embedded within the primary target volume. METHODS AND MATERIALS: IMRT fractionation regimens are specified in terms of "normalized total dose" (NTD), i.e., the biologically equivalent dose given in 2 Gy/fx. A linear-quadratic isoeffect formula is applied to convert NTDs into "nominal" prescription doses. Nominal prescription doses for a high dose to the primary disease, an intermediate dose to regional microscopic disease, and lower dose to electively treated nodes are used for optimizing IMRT plans. The resulting nominal dose distributions are converted back into NTD distributions for the evaluation of treatment plans. Similar calculations for critical normal tissues are also performed. Methods developed were applied for the intercomparison of several HN treatment regimens, including conventional regimens used currently and in the past, as well as SIB strategies. This was accomplished by comparing the biologically equivalent NTD values for the gross tumor and regional disease, and bone, muscle, and mucosa embedded in the gross tumor volume. RESULTS: (1) A schematic HN example was used to demonstrate that dose distributions for SIB IMRT are more conformal compared to dose distributions when IMRT is divided into a large-field phase and a boost phase. Both were shown to be significantly superior compared to dose distributions obtained using conventional beams for the large-field phase followed by IMRT for the boost phase. (2) The relationship between NTD and nominal dose for HN tumors was found to be quite sensitive to the choice of tumor clonogen doubling time but relatively insensitive to other parameters. (3) For late effect normal tissues embedded in the tumor volume and assumed to receive the same dose as the tumor, the biologically equivalent NTD for the SIB IMRT may be significantly higher. (4) Normal tissues outside the target volume receive lower dose due to the higher conformality of the IMRT plans. The biologically equivalent NTDs are even lower due to the lower dose per fraction in the SIB strategy. CONCLUSIONS: IMRT dose distributions are most conformal when designed to be delivered as SIB. Using isoeffect radiobiological relationships and published HN data, fractionation strategies can be designed in which the nominal dose levels to the primary, regional disease and electively treated volumes are appropriately adjusted, each receiving different dose/fx. Normal tissues outside the treated volumes are at reduced risk in such strategies since they receive lower total dose as well as lower dose/fx. However, the late effect toxicities of tissues embedded within the primary target volume and assumed to receive the same dose as the primary may pose a problem. The efficacy and safety of the proposed fractionation strategies will need to be evaluated with careful clinical trials.

Dose Fractionation, Radiation↗