Search PubMedSearch

PubMed · 10172448

Using shape-memory alloys.

Abstract

Design considerations and material selection play important roles in the development of surgical instruments for minimally-invasive procedures. Substituting shape-memory or superelastic metals or alloys for conventional materials can lead to a significant improvement in the overall performance of those instruments. In addition, simplicity of design, a reduced number of parts, and ease of assembly and disassembly result in cost reductions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Melzer, D Stöckel. 1995. Using shape-memory alloys.. https://pubmed.ncbi.nlm.nih.gov/10172448/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Glass-based coatings for titanium implant alloys.

Glass coatings on Ti6Al4V were prepared using a simple enameling technique. The composition of the glasses was tailored to match the thermal expansion of Ti6Al4V. By controlling the firing atmosphere, time, and temperature, it was possible to control the reactivity between the glass and the alloy and to fabricate coatings (25-150 micron thick) with excellent adhesion to the substrate. The optimum firing temperatures ranged between 800 and 840 degrees C at times up to 1 min in air or 15 min in N2. The same basic technique was used to prepare multilayered coatings with graded composition or with hydroxyapatite (HA) particles embedded in the outer layer. Some of these coatings presented excellent adhesion to the substrate and were able to form HA during in vitro tests in simulated body fluid.

Alloys

Hydroxyapatite thin films deposited onto uncoated and (Ti,Al, V)N-coated Ti alloys.

Plasma-sputtered hydroxyapatite (HA) thin coatings ( approximately 1 microm) were deposited onto uncoated and (TiAlV)N-coated Ti-6Al-4V-alloy substrates at low temperatures. The (TiAlV)N coating interlayer was deposited by reactive sputtering. Depositions were achieved by utilizing unbalanced and balanced magnetrons in a capacitively coupled RF plasma. Characterization of the thermostability, bioerosion resistance, and chemical composition of the coating layer was examined by scanning electron microscopy (SEM), energy-dispersive X-ray analysis (EDX), and Fourier transform infrared spectroscopy (FTIR). The results show that for deposition temperatures as low as 67 degrees C, the crystalline phase of the HA coating still is clearly detectable and that the underlying (TiAlV)N coating can increase the crystallinity and thermostability of the HA coating before and after heat treatment. The thin ( approximately 1 microm) sputtered HA coating shows strong HA characteristic peaks in the FTIR spectra even after a 30-day dissolution test. The experimental results show that a multilayer structure comprised of a bioinert (TiAlV)N and bioactive HA coating has the potential to improve the biocompatibility of implant materials. The bioinert (TiAlV)N coating also may provide a long-term stable interface between bone tissue and an alloy implant after the bioactive HA coating is remodeled by the surrounding tissue.

Alloys

Using capillary electrophoresis to study the chemical conditions within cracks in aluminum alloys.

The environment-assisted cracking (EAC) susceptibility of some aluminum alloys used for airplane structural components currently limits their use in the peak strength condition. Understanding the mechanism of EAC will facilitate the development of crack-resistant alloys with optimum mechanical properties. One component towards understanding the fundamental processes responsible for EAC is a comprehensive knowledge of the chemical conditions within cracks. The present work uses capillary electrophoresis (CE) to quantify the crack chemistry in order to provide insight into the nature of the mechanism controlling cracking. The highly restricted geometry of cracks in metals means that a crack typically contains less than 10 microliters of solution. The high mass sensitivity combined with the inherently robust nature of CE makes it an ideal analytical technique for this application. Complicating factors in the accurate determination of the crack environment include high levels of sodium present from the test solution. Low sample volume and analyte matrix complexity necessitated the development of specific sampling, extraction and analysis methods. Analysis of the crack solutions in EAC-susceptible material revealed high levels of Al3+, Mg2+, Zn2+, and Cl- near the crack tip. Cations arise from the anodic dissolution of the alloy, whereas chloride ingress from the external environment occurs to maintain solution electroneutrality within the crack. In contrast, EAC-resistant material exhibited significantly lower concentrations of dissolution products.

Alloys