Search PubMed⌕ Search

PubMed · 10149575

Interventional cardiac catheterization.

Abstract

The use of the pediatric cardiac catheterization laboratory as a therapeutic modality has become standard practice in most pediatric cardiology centers. Accordingly, reviewing the results of this form of therapy has become very important. This review focuses on the initial and long-term results of balloon dilation procedures in infants and children. As the efficacy and safety has been proven for these early procedures, dilatation therapy has become available for the critically ill neonate with pulmonary and aortic stenosis. The usefulness of implantable devices for closing abnormal shunt pathways, such as the patent ductus arteriosus and atrial septal defect, has become clear. The importance of both transthoracic color-flow Doppler and transesophageal echocardiography in proper placement and follow-up of these implantable devices is now becoming apparent and also will be evaluated in this review.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W E Hellenbrand. 1991. Interventional cardiac catheterization.. https://doi.org/10.1097/00001573-199102000-00018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Immediate hemostasis of the femoral artery after heart catheterization: the present situation of closure systems].

The femoral approach is the most commonly used route for diagnostic cardiac catheterization and coronary interventions today. Manual compression and pressure bandages usually lead to immobilisation of the patient for several hours and may result in significant discomfort. Since the introduction of the first femoral closure device in 1991, many devices have proven their efficacy in significantly reducing time to hemostasis while simultaneously improving patient comfort. Twenty four closure device systems with different concepts are on the market, e. g. pure collagen, collagen + thrombin, collagen + anchor, vascular suture, hemostatic patches and pads, staples and more. The four predominantly used are Angio-Seal (46 %), Perclose (32 %), VasoSeal (14 %) and Duett (3 %). The effectiveness of all four systems has been proven in a prospective, randomized, controlled multicenter trial each. Efficacy and safety were analyzed using data from ten comparative studies in 8832 predominantly or exclusively interventional patients, however none of the closure systems proved to be superior. Fortunately, recent years have shown a trend toward a reduction in local complications by vascular closure devices compared to manual compression. Closure devices are thus becoming increasingly cost effective. Vascular closure systems should be preferred when the prolonged supine position is not tolerated, a protein IIb/IIIa-inhibitor was used during the procedure, or early discharge of patient is anticipated. In the presence of peripheral vascular disease, small diameter of the femoral vessels or stenotic lesions in the femoral artery, closure devices should be used with caution. Closure systems for immediate femoral puncture site hemostasis are now an important tool of invasive cardiology today.

Cardiac Catheterization↗

Transcatheter device closure of congenital and postoperative residual ventricular septal defects.

BACKGROUND: Our purpose was to describe a 13-year experience with patients undergoing transcatheter device closure of unrepaired congenital or postoperative residual ventricular septal defects (VSDs). METHODS AND RESULTS: Since 1989, 170 patients (median age, 3.9 years) have undergone catheterization for closure of 1 or more congenital (n=92) or postoperative (n=78) residual VSDs using successive generations of STARFlex-type devices. Outcomes included echocardiographic assessment of residual flow and device position, assessment of VSD shunt/severity, and adverse events. Among 168 patients in whom device implantation was performed, between 1 and 7 devices were placed per patient (median, 1), with multiple devices placed in 40%. There was a significant decrease in left-to-right shunting after device implantation (P<0.001) and significant improvement in VSD size/severity, and device position proved stable. Of 332 adverse events, 39 were related to the device and 261 were related to the catheterization; all but 5 occurred in the periprocedural period. At a median follow-up of 24 months (0 to 154 months), 14 patients had died and 18 had device(s) explanted. CONCLUSIONS: Congenital and postoperative VSD closure using STARFlex-type devices resulted in stable improvement in clinical status and decreased interventricular shunting. Although periprocedural events occurred frequently, late events caused by the device were rare. Transcatheter device closure is an effective management option for patients with complex muscular VSDs that are difficult to approach surgically and for postoperative residual VSDs.

Cardiac Catheterization↗

Creation of an atrial septal defect in utero for fetuses with hypoplastic left heart syndrome and intact or highly restrictive atrial septum.

BACKGROUND: Infants born with hypoplastic left heart syndrome and an intact or highly restrictive atrial septum face a neonatal mortality of at least 48% despite early postnatal left atrial decompression and palliative surgery. Prenatal left atrial decompression has been suggested as a means of improving these outcomes. This study reports the feasibility of fetal catheterization to create an interatrial communication and describes technical considerations. METHODS AND RESULTS: Seven fetuses at 26 to 34 weeks' gestation with hypoplastic left heart syndrome and intact or highly restrictive atrial septum underwent attempted prenatal intervention. Under ultrasound guidance, the atrial septum was approached with a needle introduced percutaneously from the maternal abdominal surface. In 6 of 7 fetuses, the atrial septum was successfully perforated, with balloon dilation of this iatrogenic defect resulting in a small but persistent interatrial communication. There were no maternal complications. One fetus died after the procedure. The remaining fetuses were liveborn at term, although 4 died as neonates. CONCLUSIONS: Ultrasound-guided fetal atrial septoplasty consisting of septal puncture and balloon dilation is feasible and can be performed percutaneously to minimize maternal risk. Although we have not demonstrated any positive clinical impact to date, it is our hope that further technical evolution will ultimately enable prenatal left atrial decompression and improvement of outcomes in fetuses with hypoplastic left heart syndrome and intact atrial septum.

Cardiac Catheterization↗